Yes

<<>>

In North America, a three wire 120/240 volt system uses a neutral wire. For 240 volts two "hot" wires are used with no neutral.

User Avatar

Wiki User

11y ago

What else can I help you with?

Related Questions

Is red or white neutral for electrical work?

In residential wiring the white wire is neutral on the 120 volt circuits. On a 3way circuit the red is the traveler and the white is neutral. On a 240 volt 3 wire connection the white &amp; black are hot. On a 240 volt 4 wire connection the black and red are hot and the white is neutral.


Is red neutral or live in a 240 volt system?

The colour red designates that the wire is used as a live wire. The neutral wire is identified as white in colour.


240 volt what is loop is it neutral?

A 240-volt circuit typically consists of two hot wires and a ground wire, with no neutral wire. The hot wires each carry 120 volts, while the ground wire is used for safety purposes. In a 240-volt circuit, the hot wires complete a loop by connecting to a load or device that requires the higher voltage to operate.


How do you wire a 120 volt gfci into a 240 volt three wire?

You can't. The 120 volt GFCI is probably just a 2-wire (hot, neutral and ground) You would have to run a new 3-wire (2 hots, neutral and ground). The two hots are how you get the 240 volts (120+120=240). Also you must make sure the wire is gauged properly. #10 wire for 30 amps, #12 wire for 20 amps, etc.


Why use 3 wire 240 volt receptacle instead of a 4 wire 240 volt receptacle?

Use the 4 wire if possible. You would only use a 3 wire for an old appliance.You shouldn't if possible. The 3 wire has no neutral wire as the 4 wire does. Som applications require the use of a 3 wire and some don't.


Can you wire usa 4 wire 240 volt to UK 3 wire 240volt American boat in UK waters?

A four wire plug suggests to me that it is for split voltages. 120/240, hot - neutral - hot - ground will be the four blade connections for shore power in the US. With UK shore power three wire there will be no neutral as you know it. 120 volt equipment will not work. If there is a special berth for 120/240 shore power that is what you will need to tie up to.


Can you use 240 volts with a 120 volt supply?

No, it is not possible to use 240 volts with a 120 volt supply directly. You would need a transformer to step up the voltage from 120 volts to 240 volts. Attempting to use 240 volts with a 120 volt supply without a transformer can damage equipment and pose a safety hazard.


Is a 220 volt electrical power wire the same as a 240 volt electrical power wire?

Yes 220 &amp; 240 are considered the same.


Can you wire a 240 volt window ac from a 277 volt feed?

no


If a receptical outlet doesn't have neutral wire where is my problem?

The receptacle that you are looking at might be a 240 volt receptacle and that is the reason, there is no neutral needed. You should be able to tell by the configuration of the blade pattern if it is rated for 240 volt operation.


Does the ground wire from a 240 volt tankless water heater connect to the common wire?

Any ground wire has to be connected to an independent ground wire that returns directly to the distribution panel and not to the neutral of the circuit.


How do you size the neutral in a 240 volt system?

On a 120/240 volt distribution the neutral is sized along with the supply conductors. The sizing is based on the amperage of the service distribution.