How neitral displacement occurs?

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Electrical Engineering

What is the oscillating neutral in transformer?

An 'oscillating' neutral can exist when the star point of a three-phase, star (wye) connected, secondary winding becomes disconnected from earth (ground) -e.g. if copper thieves have removed the earth conductor or it simply becomes disconnected. This results in a 'floating neutral', in which the phase voltages are no longer necessarily equal to each other (in other words, the three phase voltages have become 'unbalanced') the extent to which depends upon how unbalanced the supplied load is. An 'oscillating' neutral occurs when the displacement of the neutral point changes as it responds to changes in the unbalanced load currents.


What is linear displacement?

It is a line that is out of place


Why no electric shock from neutral line?

There is normally no voltage on the neutral line because the neutral line is grounded. However, and this is always important, do not assume that neutral is grounded, nor that there is not an elevated voltage on neutral or ground due to a possible ground fault.


How does the Neutral Displacement Relay is working?

It checks for the sum of phase currents which is meant to be zero in case of Star point Grounded transformer. In case of any discrepancy i.e star point shifting with respect to one of the phases the sum of currents stands no longer null. This is when our NDR comes into play as it will avoid whole feeder tripping in case of 2nd fault occurring on the same transformer.


What does floating neutral mean on a generator?

It means the neutral is not grounded.

Related Questions

How the Neutral displacement occures?

In a three phase connected system, if the loads are not balanced or if one voltage is disconnected due to any reason there will be neutral displacement to a new voltage level (from normal zero voltage). This can increase/decrease voltage in other phases


What is neutral displacement relay?

YES


What is neutral displacement?

YES


PLMD occures most of?

PLMD occures most often in first stage of sleep but can be seen in other stages as well.


What is vdg14 neutral displacement relay?

VDG14 is a type of neutral displacement relay used in electrical systems to protect against earth faults. It operates by measuring the current flow in different phases and the neutral conductor to detect any imbalance that may indicate a fault. This relay helps to quickly isolate the faulted section of the system to prevent further damage.


Why control valve hunting occures?

oversize for its use


What part of the cell does DNA occur in?

It occures in the nucleus


What occures during freezing and melting?

a change of state


What shape would the graph of U versus x have if a particle were in a region of neutral equilibrium?

In neutral equilibrium, displacement in either direction would not affect the potential energy of the particle, therefore, the graph would be horizontal.