Tie all White wires together.
Tie the Grounds together and connect them to the ground screw on two switches.
Create a pigtail with TWO black wires coming out.
Connect a black wire to each of the two switches. (you pick which screw, but be consistent.
Connect the black wire from the light to the remaining screw on one of the switches.
Connect the black wire from the fan to the remaining screw on the OTHER switch.
run in a electrical system means a wiring & conduit runs coming from Panel Board Circuit Breaker to its branch circuit loads in a circuit. while circuit is a designated number of branch breaker in a panel board where power load was individual connected.
simple what goes in comes out mains has a % mark of around 10% under or over so that's not un normal to see this info
The question doesn't say what "the box" refers-to: is it a wall box for a socket outlet or is it for a switch - or is it actually the main circuit breaker panel for the building or apartment?You can add a safety ground wire to any wall box - to connect appliances back to the ground on main breaker panel - only if there is a main grounding wire installed at your main breaker panel.You can't add a safety ground wire to any wall box, to connect appliances back to the main breaker panel, if you don't already have a ground wire installed at your main breaker panel. If that is the case, your wiring must be at least 50 years old. It is time to consult with an electrician...As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
A circuit breaker is a device that opens its contacts in order to open the circuit in case of current overload. A differential circuit breaker is a device that opens the circuit in case of leakage (current measured on the phase line is differentthan the current returned to neutral line); therefore protects users from electric shocks.To more understand how it operates, consider the following:Say that your electrical wall outlet is connected to a differential breaker. When plugging let's say a hair dryer to it, the current traveling on the phase line (going into the hair dryer and out to the neutral line of the wall outlet) equals but in reverse direction of the current returned to the neutral line, thus the difference is zero. Now let's say this hair dryer got faulty and fraction of the current coming from the outlet phase line travels through your body and return to earth (considering that you are not electrically isolated from the ground). Thus the current in neutral line is less than the current on phase line; at this moment the difference is not zero and breaker opens to protect you from getting electrocuted.
There should be no noise caused by loose electrical connections if the main breaker is off. The only places that are energized at that point are the main lugs. There is nothing running so there shouldn't be any current which is the only reason a loose connection can cause noise. But all that is based on what SHOULD be happening. If someone has tied into the mains to feed something then there could be noise caused by loose connections. Another possibility is something mechanical causing the panel to vibrate. Tightening the mounting screws might be sufficient to solve this problem.
If it's coming from the roof then the bathroom ceiling will have a water stain on it too. If you don't see this then it is coming from your bathroom.
Yes, it is recommended to recite the dua "Ghufranak" (meaning: I seek Your forgiveness) after coming out of the bathroom.
Look, watch, and listen to make sure a train is not coming.
You need to call a plumber.
Maybe Eurelieved (you're relieved).
Possible causes of a sewage smell coming from the bathroom sink include a dried-out P-trap, a clog in the drain, or a problem with the sewer venting system.
Cats may cry when you go to the bathroom because they are anxious about being separated from you or they are seeking attention. They may also be curious about the sounds and smells coming from the bathroom.
Nobody saw anything coming.
The bad odor coming from your bathroom sink could be caused by a buildup of bacteria, mold, or debris in the drain or pipes. Regular cleaning and maintenance of the sink can help eliminate the odor.
The unpleasant smell coming from your bathroom sink could be caused by a buildup of bacteria, mold, or debris in the drain or pipes. It is recommended to clean the drain and pipes thoroughly to eliminate the odor.
It controls the amount of light coming up into the objective lens.
To determine if a breaker is bad, you can visually inspect it for any signs of damage or wear, test it with a multimeter to check for continuity, and also listen for any unusual buzzing or humming sounds coming from the breaker. If the breaker repeatedly trips or fails to reset, it may indicate that it is faulty and needs to be replaced.