answersLogoWhite

0

Answer for USA, Canada and countries running a 60 Hz supply service.

The wiring of this type of installation is quite elementary. It is all about the control voltage for the magnetic contactor and having the pressure switch in series with the contactor's coil.

If the pump supply voltage is 120 volts, take a wire from L1 on the contactor and place it on the normally closed contact point on the overload block.

From the N.C. contact on the overload block take a wire to one side of the pressure switch.

From the output side of the pressure switch contact take the wire back to one side of the contactor's coil.

Connect the other side of the contactor's coil to the neutral wire from the supply.

Now you will have three components in series with each other. The overload block, the pressure switch and the contactor's coil as the load of the circuit. When the pressure switch closes due to low pressure the coil will be energized.

If the pump motor goes into an overload condition, the overload block contacts will open and de-energize the contactor's coil and the pump will shut off.

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Electrical Engineering

What are relay switches?

a relay switch can be used to control one voltage from another(e.g. 24 volt controlling a 120v circuit), or controlling multiple functions and circuits from one voltage switch or location. advantages to relays are that the size of conductor can be greatly reduced with a lower voltage(cost and ease of installation) and consumer convienience(one switch for 100 lights or one photocell controlling an entire parking lots lighting even with a rating of 15 amps)


What is a hydropneumatic system?

Hydropneumatic SystemThe hydropneumatic system consists of a pressure vessel and a pressure pump. The pressure vessel contains water with a pressurized air space to provide the pressure for the system. With water demand, water flows from the vessel, increasing the air space as well as decreasing air pressure. This lower pressure signals the pump to start. The pump meets the demand with the excess volume backing up in the pressure vessel. This decreases the air space and increases the pressure once again. When the upper level is reached, the pump shuts off. The newer pressure vessels have a neoprene bladder to separate the air space from the water.These systems are common in homes with an individual well system. They typically provide adequate pressure but low volume. They are ideal for a rural water system that has a limited service area that is elevated from the main line resulting in inadequate pressure. Hollows, cul-de-sacs, and small trailer parks utilize these to increase pressure. Some water systems have small hydropneumatic stations added as the system expands. These stations are relatively inexpensive to engineer and construct and are often available as package units.Some of the problems with hydropneumatic stations are that while they provide adequate pressure, they provide limited volume. In some instances, with the nonbladder pressure vessels, air may be forced into the water lines if the demand for water exceeds pump capacity. Also, if the air space in the vessel is lost due to leakage (waterlogging), the pressure pump will stop and start too frequently, resulting in erratic pressure and low water volume. Also, pressure will not last long during power outages.


Will your electric water heater blow up if your water is turned off?

Only if you leave the burners or elements on. -If water stops, close gas line or switch off breaker for tank.


What is a shunt in the head?

A shunt is inserted in the head to relieve water pressure on the brain.


What equipment is needed to use hydroelectricity?

To tap hydroelectricity, there must be a dam which can store water and let it flow rapidly through a sink hole. The pressure of the falling water can drive generator turbines and these will generate electricity.

Related Questions

Pressure switch does not switch off?

switch is frozen from water corrosion.


How can I adjust the water pressure switch to optimize the performance of my water system?

To adjust the water pressure switch for optimal performance, locate the switch on your water system and use a screwdriver to adjust the pressure setting. Increase the pressure if you have low water pressure and decrease it if the pressure is too high. Test the water flow after each adjustment to find the optimal setting for your system.


How do i maintain water pressure in my well?

with a pressure tank and pressure switch


How to adjust the water pressure switch for optimal performance?

To adjust the water pressure switch for optimal performance, locate the switch on the water pump and use a screwdriver to turn the adjustment nut clockwise to increase pressure or counterclockwise to decrease pressure. Test the water pressure after each adjustment to ensure it is at the desired level.


What is the function of a pressure switch for a well pump and how does it regulate the water pressure in the system?

A pressure switch for a well pump is a device that turns the pump on and off based on the water pressure in the system. When the pressure drops below a certain level, the switch activates the pump to increase the pressure. Once the pressure reaches a set point, the switch turns off the pump to maintain a consistent water pressure in the system.


What is the function of a water pump pressure switch in a plumbing system?

The function of a water pump pressure switch in a plumbing system is to automatically control the operation of the water pump based on the water pressure in the system. When the pressure drops below a certain level, the switch activates the pump to increase the pressure, and when the pressure reaches a set point, the switch turns off the pump to prevent over-pressurization.


How can I adjust the water pressure switch to ensure optimal performance in my plumbing system?

To adjust the water pressure switch for optimal performance in your plumbing system, locate the switch on your water pump and use a screwdriver to adjust the pressure settings. Increase the pressure if water flow is weak, and decrease it if there is too much pressure. Be sure to follow the manufacturer's guidelines for the specific switch model.


How can I adjust the water pressure switch in my plumbing system to ensure optimal performance?

To adjust the water pressure switch in your plumbing system for optimal performance, locate the pressure switch on the water pump and use a screwdriver to adjust the pressure setting. Turn the screw clockwise to increase pressure and counterclockwise to decrease pressure. Be sure to consult the manufacturer's instructions for specific guidance on adjusting the pressure switch.


What is good water pressure from a well?

The water pressure from a well is controlled by a pressure switch with a low setting of about 20 psi and a high setting of about 40 psi. It is adjustable for both high and low pressure and some wells, depending upon the pump capability will run from 40 psi low to 60 psi high.


How can I adjust the well pump pressure switch to ensure proper water pressure in my system?

To adjust the well pump pressure switch for proper water pressure, locate the switch on the pump and use a screwdriver to adjust the pressure settings. Increase the pressure by turning the screw clockwise and decrease it by turning it counterclockwise. Test the water pressure after each adjustment until it reaches the desired level.


How can I adjust the well pressure switch to ensure optimal performance of my water system?

To adjust the well pressure switch for optimal performance of your water system, follow these steps: Turn off the power to the well pump. Locate the pressure switch, usually near the pressure tank. Use a screwdriver to adjust the cut-in and cut-out pressure settings on the switch. Increase the cut-in pressure if the water pressure is too low, and decrease it if the pressure is too high. Adjust the cut-out pressure to a level that provides consistent water pressure. Turn the power back on and monitor the system for any changes in water pressure. Remember to consult the manufacturer's instructions for specific guidance on adjusting the pressure switch.


How much pressure should a water bladder tank hold?

It depends on which pressure switch you have. The total pressure with a 60-80 switch is about 84 psi.