You will need a receptacle that you can wire each outlet separately (not jumpered). You would then wire the switch in series on the line conductor with the outlet you want switchable. Wire the other outlet directly to the power source. You can jumper the neutral from one outlet to the other.

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Electrical Engineering

How do you install a GFCI so it is always on to a two way light switch that controls a vent and a light in a bathroom?

Your question sounds simple but it isn't. There are two ways of wiring a light to a switch. One is to bring the hot and neutral wire to the switch box and from there run wires from the switch to the light. If this is the case you can install a GFCI on the circuit. The other way is to bring the hot and neutral wire to the light and from there run two wires to the switch and switch the light that way. In this case you cannot install a GFCI to in the switch box. <<>> The way you want the circuit to work has to be laid out as follows. Method one, the circuit that now controls the bathroom devices can be changed to a GFCI breaker. This is probably the quickest and cheapest, unless the job is new construction. Method two, if new construction use this method, as tearing walls open to get to the wiring will become costly. Where a supply circuit comes from the service distribution panel the first device on that circuit has to be a GFCI receptacle. This device has secondary terminals on it, that if connected every device downstream from it will also be protected. So if you supply the two way light switch that controls the vent fan and a bathroom light from the secondary terminals from the GFCI receptacle they will be protected.


Power is not off . need to change when you change the light switch?

Yes, you need to turn off the power when you change (replace) a light switch, since at least one of the terminals on the switch will always have power if the circuit is energized at the panel.


Can you use a 15amp outlet on a 20amp circuit?

No. You aren't allowed to install a device rated greater than the circuit is rated.The 20 amp receptacle would allow you to plug in 20 amp loads (which is why it is different than a 15 amp receptacle), and plugging a 20 amp load into a 15 amp circuit would cause an overload and the 15 amp circuit breaker would trip.ADDITIONThis may still be open for discussion. According an electrician from RKO Electric, you can in fact install a 20 Amp GFCI receptacle on a 15 Amp breaker. Apparently, the breaker will trip well before the receptacle is able to pull 20 Amps of current into the line. Please see the following link from another website: http://en.allexperts.com/q/Electrical-Wiring-Home-1734/20-amp-GFCI-outlets.htm2003 NEC Code Book says:210-21(b)(1), p.70-42: A single receptacle on an individual branch circuit shall have an ampere rating of not less than that of the branch circuit. To me this indicates that if there's only one receptacle on the circuit, you can't have an outlet rated for less than the circuit, but it neither mentions nor prohibits oversizing the receptacle.210-21(3), p.70-42: Where connected to a branch circuit supplying two or more receptacles or outlets, receptacle ratings shall conform to the values listed in table 210-21(b)(3)... which says: 15amp circuit, not over15amp receptacle (


Is it necessary to ground an outlet?

If the receptacle has a ground terminal (green screw) and has three prongs, you must connect a ground wire if it is a new installation. There is one exception to this: if the three prong receptacle is fed from the LOAD side of a GFCI receptacle, it is not required to have a grounding conductor. This is because the receptacle is considered to be protected by the GFCI's function. In addition the GFCI itself is not required to have a ground connected. In these cases the receptacle needs to be labeled "no equipment ground" on the wallplate. If this is existing, you are usually not required to correct things that were not originally done to code. However a three prong receptacle should not be used as such if it does not have a grounding conductor connected. This would lead to a false sense of grounding and safety.


Does a microwave always need a dedicated circuit?

No

Related Questions

Always treat electrical wires in a circuit as being?

Energized.


When wiring is electrically connected to a source of voltage is should be considered energized?

Because it is your life you should always think that what ever you are going to work on is hot or energized. That is what they make meters for to tell you if the circuit is dead or energized what do you do if the neutral is broke or open.


What is the proper way to test a receptacle?

The simplest way to test a receptacle is to use a plug-in type receptacle tester. This tester indicates either proper operation or common miswirings of the receptacle. If the receptacle is a GFCI, there is a special type of plug-in tester that has a GFCI trip button on top. This tester indicates the same things as the other one. In addition, you can press the test button to create a small ground fault, which will trip a properly operating GFCI. ---- IF YOU'RE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.If you do any work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work and always use a meter or voltage indicator to insure the circuit is, in fact, de-energized.


How many volts come out of a average outlet?

Voltage does not come out of an average home outlet under normal circumstances.In North America the common potential voltage is 120 volts and is always at the receptacle as long as the circuit is energized. When an electrical device is plugged into the receptacle, through the device's connected cord, this brings the potential supply voltage to the electrical device.When the device is turned on a current (amperage) will flow, governed by the resistance of the device. If it is a lamp, it will become bright. If it is a radio you will hear sounds.When you unplug the electrical device from the receptacle, the device will stop operating but the voltage potential will still remain on the "hot" side of the receptacle's blade contact point.


What causes a crackling noise from an electric socket?

A crackling noise from a receptacle indicates an arc fault. It's the arc (electricity trying to jump across an air gap to return to its source) that you are hearing. There's most likely a loose connection on/in a receptacle. You should turn off the breaker for the circuit in question and consult a professional electrician. An arc fault can cause fire if uncorrected. ---- IF YOU'RE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS. If you do this work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicator to insure the circuit is, in fact, de-energized.


How do you wire a NEMA L5 30 receptacle?

A Nema L5-30 receptacle is similarly wired like a standard receptacle except all wires are sized to #10 including the ground and supplied by a 30 amp single pole breaker. It has a neutral (white) to pin W, hot (phase color) and ground (green) to pin G.The L indicates that it is a lock type receptacle, so the face is circular with 3 openings in a concentric shape. As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


How many outlet can you have in one circuit in a industrial job?

Answer for USA, Canada and countries running a 60 Hz supply service.On a 20 amp circuit you can have 13 receptacle outlets.On a 15 amp circuit you can have 10 receptacle outlets.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What is wrong if you installed a gfci in the bathroom according to instructions and when the test button is pushed the lamp plugged into the adjacent bedroom socket goes off?

The "TEST" button is there for you to check the GFCI is operating correctly. When you test the GFCI using its Test button it should trip to break the circuit. Then anything connected to that circuit will have no power. It sounds like the light in the other room is wired to the same circuit as the one you are working on, so, if the GFCI is tripped - such as when you press the Test button - no outlet in that circuit will be able to work until you reset the GFCI using its "RESET" button.If what happens is as was just described then your GFCI is working as it was designed to do. If you are talking about a GFCI receptacle, and wired the receptacle as it shows you how to on the instruction sheet, then everything down stream from the receptacle is protected, along with the actual receptacle that you just installed. The bottom set of terminals on the receptacle that states the word "load", is where the wires leaving the receptacle box should be connected to. Incoming power to the top terminals of the receptacle outgoing power to the next receptacle to the bottom terminals. This allows the GFCI receptacle to protect every other receptacle that is connected down stream on that circuit. If you check closely to the other receptacles that are connected, you will find that they also will be off when you push the test button. ----- As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed. Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


How do you test and reset a GFCI receptacle?

GFCI (Ground Fault Circuit Interruptor) A GFCI receptacle can be tested with the built-in test button, which will cause a small ground fault, tripping a properly working device. GFCI receptacles should be tested monthly. GFCI receptacles can also be tested with a plug-in type GFCI tester. This tester has a GFCI trip button on it which accomplishes the same thing as the built-in test button. Your local inspector will usually test with this method. If your receptacle is tripped, it should reset by pressing in the reset button. If it doesn't, the device is wired incorrectly, has a faulty load plugged into it, or is simply in need of replacement. ---- IF YOU'RE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.If you do this work yourself, always turn off the powerat the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicator to insure the circuit is, in fact, de-energized.


Why switch is always connected in the phase?

Switches are used to isolate the supply voltage from the connected load. This isolation is needed to be able to work on equipment in the de-energized state. Without the switch in the circuit this could not be accomplished.


How do you convert a 120V receptacle to a 240V receptacle for a European stereo system that uses 230V if the Stereo has no toggle switch to 110V like some units on the market?

You can't "convert" a 120V receptacle into a 240V receptacle.A proper new 240V branch circuit complete with correctly sized circuit breakers, wiring and socket outlet is required.For more information see the Related Question shown below.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


How do I fix a dishwasher that in it's heating phase keeps tripping the GFCI receptacle which is upstream from it?

Sounds like the heating element is internally grounded and should be replaced. It could also be water leaking past a seal somewhere dripping on a wire or terminal. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS. If you do this work yourself, always turn off the power at the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicatorto insure the circuit is, in fact, de-energized.