If you are replacing a stat simply put the colors back to the terminals they came off of. If this is a new install R= 24v control power supply from the source(usually the air handler). Y=cooling,W=heating and G=fan. Y,W & G all send control power back to the unit and their respective relays. Y will need to go to the outdoor unit along with a common,as that is the control wire for the compressor. G will go to the fan relay terminal in the air handler and W will go to the heat relay terminal for the gas valve also in the airhandler. If you have RC & RH instead of just R they can be jumped together if you have a single control power source. If you have 2 control power sources RH & W need to use one and RC,Y & G would use the other.
Disconnect power to geyser and remove the thermostat. Turn heat selector to maximum and with the thermostat removed from the geyser and electrical wiring, test for continuity between the input and output sides of the (L)ive side. If there is continuity the thermostat is ok and the fault may then lie with the element.
2 wires to the "R" and "W" terminals on the furnace. Usually the thermostat has similar terminals. If you have air conditioning, then there are 5 terminals to contend with. Look for a wiring diagram on the internet.
A central air conditioning unit will commonly turn on and off intermittently. To stop this, adjust the temperature on the thermostat or switch the unit either on or off rather than the automatic setting on the thermostat.
There are many sites on the internet where you can search for manuals for different types of equipment.
I think by 'cross wiring' you mean reverse polarity. This means the hot wire is connected to the neutral screw and the neutral wire is connected to the hot screw. This shouldn't have any impact on an AC motor, since AC voltage already changes polarity 60 times per second.
short in the wiring
There could be several reasons why your thermostat is not turning on the AC. It could be due to a malfunction in the thermostat itself, a problem with the wiring, a tripped circuit breaker, or an issue with the AC unit. It is recommended to check these potential issues and consult a professional if needed.
The purpose of the thermostat wires outside the AC unit is to connect the thermostat inside the building to the AC unit outside, allowing the thermostat to communicate with the AC unit and control its operation based on the desired temperature settings.
can a faluty thermostat affect your central ac working?
The correct wiring diagram for an attic fan thermostat typically involves connecting the power source to the thermostat, then wiring the thermostat to the fan motor. It is important to follow the manufacturer's instructions and ensure proper grounding for safety.
The steps involved in an AC thermostat replacement are: turning off the power to the AC unit, removing the old thermostat cover, disconnecting the wires from the old thermostat, removing the old thermostat from the wall, installing the new thermostat, connecting the wires to the new thermostat, attaching the new thermostat to the wall, and finally turning the power back on to test the new thermostat.
The fan in your AC unit may not be coming on due to a faulty motor, a malfunctioning thermostat, a blown fuse, or a problem with the wiring. It is recommended to contact a professional HVAC technician to diagnose and fix the issue.
yes Thermostat has no effect on A/C
When troubleshooting issues with an AC unit thermostat, start by checking the power source, batteries, and settings. Make sure the thermostat is set to the correct temperature and mode. If the issue persists, consider cleaning or replacing the thermostat, checking the wiring connections, and ensuring proper placement away from heat sources. If problems continue, consult a professional HVAC technician for further assistance.
wiring for sears thermostat 387.911122
The 2 wire thermostat wiring diagram for a specific model of thermostat typically involves connecting one wire to the R terminal and the other wire to the W terminal on the thermostat. This allows the thermostat to control the heating system.
To check thermostat wiring, first turn off the power to the thermostat. Remove the cover and inspect the wiring connections to ensure they are secure and not damaged. Use a multimeter to test for continuity in the wires. If there are any issues, consult a professional for further assistance.