answersLogoWhite

0


Best Answer

flue gas out

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

13y ago

larney

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How induced draft fan works?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Difference between statically and dynamically induced emf?

STATICALLY INDUCED EMFThe emf induced in a coil due to change of flux linked with it (change of flux is by the increase or decrease in current) is called statically induced emf.Transformer is an example of statically induced emf. Here the windings are stationary,magnetic field is moving around the conductor and produces the emf.DYNAMICALLY INDUCED EMFThe emf induced in a coil due to relative motion of the conductor and the magnetic field is called dynamically induced emf.example:dc generator works on the principle of dynamically induced emf in the conductors which are housed in a revolving armature lying within magnetic field


Which law gives the direction of induced current?

LENZ LAW gives the direction of induced current.


What are the reasons why a current is induced in a coil?

Current is not induced into a coil. It's voltage that is induced into a coil. If the coil is connected to a load, or even short circuited, then a current will flow as a result of the induced voltage -but it's the voltage, not the resulting current, that's induced!Voltage is induced into a coil because the the changing magnetic field, due to the change in current (0 to Imax or vice versa) applied to that coil. The process is called 'self induction'.


Why does a transformer need continuous rise and fall of current to induce a current into the secondary windings?

That is how inductance works. The rise is needed to charge the primary. When the field collapses, that is when the current is induced in the secondary winding(s).


How is the induced voltage of separately excited dc generator affected if the speed increases?

as speed increases, induced voltage increases

Related questions

Why induced draft fan capacity is more compare to forced draft fan in power plant?

Because it is induced


What is an induced-draft air-cooled condenser?

relies on natural convection and doesn't use a fan


Forced draft fan vs induced draft fan?

In a balanced draft boiler, you actually have both: forced draft (FD) fans supplying air to the furnace, and induced draft (ID) fans removing flue gas. Typically, the FD fans control airflow, while ID Fans control furnace pressure to slightly below atmospheric pressure. In general though, the choice between forced draft and induced draft is based on how "tight" the system is - if you have leaks, it is better to use ID, as FD will cause product loss.


Can Forced draft fan can be used as a induced draft fan?

A forced draught is where the air flow comes directly from the fan to the object. Such as an hair dryer.An induced draught is where the air flow is induced {lit lead in} by a separate flow of air. For example, an abrasive jet would quickly wear out if the abrasive passed through the jet nozzle. the flow of abrasive is added (induced) into the air flow by a jet of clean air.If an air flow is corrosive or very dirty then an induced flow system would be appropriate.


Is forced draft has negative pressure drop?

No, the forced draft fan has positive pressure as it just forces yhe air into the combustion chamber.only the induced draft fan has negative pressureas it removes the flue gases & exhaust gases is stacked up


Why induced draft fan operate first instead of a forced draft fan?

The procedure for starting draft plant (fans) in a boiler is to start the ID Fan first. Remember that the purpose of the ID Fan is so that the Furnace operates at a slight vacuum. (See Related Link: FD Fan vs ID Fan.) Any casing or furnace leaks then allow air to leak in, rather than allowing air with pulverised fuel and fly ask to leak out.


What is the difference between induced and forced draft cooling tower?

Induced draft --- A mechanical draft tower with a fan at the discharge (at the top) which pulls air up through the tower. The fan induces hot moist air out the discharge. This produces low entering and high exiting air velocities, reducing the possibility of recirculation in which discharged air flows back into the air intake. This fan/fin arrangement is also known as draw-through. (see Image 3)Forced draft --- A mechanical draft tower with a blower type fan at the intake. The fan forces air into the tower, creating high entering and low exiting air velocities. The low exiting velocity is much more susceptible to recirculation. With the fan on the air intake, the fan is more susceptible to complications due to freezing conditions. Another disadvantage is that a forced draft design typically requires more motor horsepower than an equivalent induced draft design. The benefit of the forced draft design is its ability to work with high static pressure. Such setups can be installed in more-confined spaces and even in some indoor situations. This fan/fill geometry is also known as blow-through.


What removes the combustion gases from a balanced draft furnace?

A balanced draft has both ID and FD fans. ID Fan works by pulling the gases through the furnace hence creating the required draft. Where as FD fan pushes the gases into the furnace. Hence in a balanced draft frunace, the ID fan can said to be removing the combustion gases.


What is a balanced draft and how is it controlled?

furnace equipped with FD(force draft) and ID(induced draft) fan /blower are called balanced draft system.Fd used to regulate combustion airflow while ID used to regulate furnace pressures type of furnace operate slightly below ATM pressure .


What is the sequence of operations of gas furnaces?

Thermostat calls for heat. Induced draft fan motor starts. Vent pressure switch verifies pressure. Simultaneously gas valve opens and ignitor lights burner(ignition varies: hot surface ignitor, electronic spark ignitor, or standing pilot). Flame is sensed. High limit temperature switch is made. Blower fan runs. Thermostat calls for no heat. Gas valves close. Burners shut off. Induced draft fan shuts off. Blower fan put into fan delay(fan blower continues to run). Low limit temperature switch made. Fan blower stops.


What type of air cooler is normally preferred forced draft or induced draftwhy?

the induced draft type is more expensive than the other type, however it is often preferred because it is more efficient.


What is the nature of stress in ceiling fan rod?

Fan on the celling which stress induced it