Best Answer

The instantaneous voltage rating of a given insulation sytem. In the case of a lightning strike, it is very high voltage but only for a split second. The insulation is designed to handle this rated voltage for a split second without damage to the apparatus. Any longer, and damage would result.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is Lightning impulse withstand voltage?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Define rated impulse voltage?

Simply, the voltage which is withstand by the test object as an impulse is called as rated impulse voltage.


Basic impulse level BIL?

The Basic impulse level is the maximum peak voltage that a piece of equipment can withstand. When you exceed this rating the insulation will break down and short out.


What is the basic insulation level of various electrical equipments?

BIL or basic impulse insulation level is the dielectric insulation gradient of a material tested to withstand the voltage stress at a voltage impressed between the material and a conductive surface beyond the BIL rating, an electric tracking starts to occur which will then result into an arcing flashover to the conductive surface. In addition it is the capacity of an equipment to withstand mechanical stress..like lightning strike without causing any damage to the equipment...


What does BIL stand for in electrical high voltage substation?

BIL stands for Basic Impulse Level, it is the impulse voltage or power ( in the case of testing a transformer) or surge voltage in the case of lightning or switching, that a transformer or any other electric device is able to with stand. It refers to maximum voltage a device can with stand with out insulation breakdown which leads to a short circuit.


What is power frequency withstand voltage test?

A test done on a transformer. The voltage at the power frequency is ramped up to verify the transformer is capable of handling the stresses due to switching and natural phenomena (lighting strikes).Withstand Voltage:The voltage which has to be applied to a test object under specified conditions in a "withstand test" is called the "withstand voltage".

Related questions

What is insulation coordination?

Lightning impulse withstand voltage


What does BIL basic insulator level really mean and its differences with Impulse withstand voltage and power frequency withstand voltage?

BIL is basic insulation level as per you or in other words it would be "basic impulse level" which implies the limit up to which an insulator could withstand impulse due to lightning strikes. Impulse is generated on the insulation due to the high voltage surges and spikes due to lightning strikes. BIL is generally much higher as compared to power frequency withstand voltage. In other words BIL is lightning Impulse withstand voltage. Impulse withstand voltage is the voltage that is generated due to switching operation and it's much higher than power frequency withstand, but BIL or the lightning withstand voltage is a the voltage level that an insulation can withstand during surge or lightning strikes.


What is the meaning of rated lightning impulse withstand voltage?

That is the voltage rating the product can stand up to. If the lightning withstand voltage was 100,000,000V, that means the item could get struck by lightning that is up to 100,000,000V without damaging it.


Define rated impulse voltage?

Simply, the voltage which is withstand by the test object as an impulse is called as rated impulse voltage.


Distance between ehv lines?

The distance between high voltage lines is governed by either a switching impulse voltage or lightning impulse voltage. The distance between lines, or lines and tower must have a high enough dielectric strength to avoid flashover at these voltage. Air can withstand a voltage of 3kv/mm.


What is BIL lightning impusle withstanding voltage 150 kv bil?

Please refer Chapter 1, Page 2 of "Insulation coordination for power systems" by Andrew R. Hileman that gives a good description of the term BIL and BSL (Basic Switching Impulse Withstand Voltage).


Basic impulse level BIL?

The Basic impulse level is the maximum peak voltage that a piece of equipment can withstand. When you exceed this rating the insulation will break down and short out.


Why negative impulse is applied during Impulse voltage test?

The lightning phenomena is occurred on transmission lines or sub-stations due to which a negative wave is generated hence definitely destroy the power apparatus. So for impulse voltage testing of any power apparatus one must produce a negative impulse.


What is impulse votage?

Sudden rise in Voltage is called Impulse voltage.


What is the basic insulation level of various electrical equipments?

BIL or basic impulse insulation level is the dielectric insulation gradient of a material tested to withstand the voltage stress at a voltage impressed between the material and a conductive surface beyond the BIL rating, an electric tracking starts to occur which will then result into an arcing flashover to the conductive surface. In addition it is the capacity of an equipment to withstand mechanical stress..like lightning strike without causing any damage to the equipment...


What does BIL stand for in electrical high voltage substation?

BIL stands for Basic Impulse Level, it is the impulse voltage or power ( in the case of testing a transformer) or surge voltage in the case of lightning or switching, that a transformer or any other electric device is able to with stand. It refers to maximum voltage a device can with stand with out insulation breakdown which leads to a short circuit.


What is mean by power frequency withstand voltage and impulse withstand voltage?

Power frequency volatge is applied for a duration of one minute and as such there would be many cycles of sinusoidal wave form applied during the tets; hence, RMS value is considered. Whereas LI is a surge and is typically 1.20 micro sec. wave; hence peak is considered.