The current path in an over current fault is the path of least resistance. Older electrical systems used to use the neutral wire for this purpose. It was found that on some occasions this was not the path of least resistance. Hence the installation of a ground wire being installed in cable sets. This innovation caused the whole grounding section in electrical code books to be rewritten. Now a specific ground wire is used to bring the fault current back to the distribution panel to trip the breaker and open the faulted circuit.

User Avatar

Wiki User

13y ago

What else can I help you with?

Related Questions

How does low impedance ground Fault current path help in the operation of the overcurrent device?

AND thennnnnnnn, comprate UN relo


What is residual earth fault protection?

Earth fault protection is protection based on ground, or zero sequence current. If current is coming up from the ground (or going down to the ground), this protection should operate. Residual usually refers to 3*I0, which is the same as the ground current, and is the vector sum of the current in all three phases. This can be measured by connected all three phase CTs in wye, and placing a single phase overcurrent relay in the wye path to ground.


What is a condition that provides an undesired path for electrical current?

The condition you are looking for is a short circuit.


What is the earth wire inside a plug for?

This wire provides a low impedance return path to the distribution panel in case of a circuit fault. This direct fault current path will trip the circuit's breaker and open the circuit.


Differetiate between solid earthing and ELCB?

ELCB is the connection to the direct earth path using protective device.while solid earthing is without protective device.A form of ELCB should be installed when direct earth path of low enough impendance can not be obtained.


What is a ground fault?

A ground fault is an electrical fault that occurs when an unintended path forms between an electrical current-carrying conductor and the ground. This can result in excess current flowing through the unintended path and can lead to shock hazards or electrical fires. Ground fault circuit interrupters (GFCIs) are used to detect and quickly stop the flow of electricity in such situations to prevent accidents.


What is meant by ground fault?

The ground ('earth'), because of its mass, is a reasonably-good conductor and is used as a 'reference' for a distribution transformer's neutral terminal. A ground fault ('earth fault') occurs when the line conductor from the distribution transformer makes accidental contact directly with the ground ('earth'). The resulting low-resistance earth path back to the transformer's neutral is such that the resulting ground-fault current('earth-fault current') will operate the transformer's overcurrent protection device (e.g. fuse).


What is the difference between an arc fault and a ground fault?

An arc fault occurs when there is an unintended electrical discharge between two conductors, while a ground fault happens when an electrical current flows to the ground instead of following its intended path.


Under what circumstances will a ground fault circuit interrupter trip when a fault current occurs?

A ground fault circuit interrupter (GFCI) will trip when it detects an imbalance in the electrical current flowing through it. This can happen when there is a fault current, such as when electricity leaks to the ground or encounters a path of least resistance. The GFCI is designed to quickly shut off power in these situations to prevent electric shock or fire hazards.


What is earth fault loop impedance?

An earth-fault loop is the path taken by the fault current, when an earth-fault occurs within an electrical installation, and comprises a series circuit made up ofthe utility company tranformer's low-voltage winding,the utility company's distribution cable's line conductor,the consumer's line conductor to the point of an earth fault,the consumer's earthing conductor,and the resistance of the earth path back to the transformer.The combined opposition of this series circuit to the flow of fault current is termed the earth-fault loop impedance, expressed in ohms.


Is a fault?

An electrical fault is where the electrical current goes where it is not intended to go. Usually this is the quickest and shortest return path to the electrical supply service. An electrical fault will trip breakers and blow fuses in the circuit as protection to stop the short circuit.


A fault is a what?

An electrical fault is where the electrical current goes where it is not intended to go. Usually this is the quickest and shortest return path to the electrical supply service. An electrical fault will trip breakers and blow fuses in the circuit as protection to stop the short circuit.