Any test equipment that your life may depend on when using it must first be tested before being used. These types of test equipment usually have internal apparatus that can verify that the equipment is working perfectly before it is used by personnel. Linesmen use this type of test equipment before working on primary voltage lines.
They must be tested for insulation in the wiring.
The National Electrical Code is the recognised standard to which all electrical wiring and installations must adhere to. It is a requirement of selling a house that all wiring and equipment must feature this code to prove it has been correctly fitted.
Working space around electrical equipment shall be minimum: 30" wide and 36" deep and 6'-6" high. The panel door must be able to open at a 90 degrees angle.
Water conducts electricity and is therefore contraindicated for use on energized electrical equipment, however it is much cheaper than the chemicals that can be used on energized equipment making it more economical when water is able to be used. Similarly water should not be used on grease fires as it will spread out the grease and the fire rather than smothering it. Water if pure without contaminants does not conduct . Having stated that electrical fire can hardly be contained by water since the air itself will conduct electrons by ionization. So to contain an electrical fire a the oxygen must be removed and water will not do that.
Obviously, an HVAC duct or pipe can pass through an electrical room, as described in the NEC. It cannot pass directly over or under panelboards, and elctrical equipment must be protected from condensation or drips form the pipe or duct.
To protect the system from faults the equipment used is known as switch gearAnswerSwitchgear is the generic name for transmission and distribution equipment designed control, disconnect, and protect an electrical system. Switchgear includes circuit breakers, fuses, and isolators (US term: disconnectors). As well as being used to control circuits by opening or closing those circuits, circuit breakers are designed to interruptand to close onto electrical faults so must incorporate means of extinguishing the arcing associated with such faults. Circuit breakers, therefore, have a essential role in responding to protection systems. Isolators are non-load breaking switches, designed to isolate equipment (including circuit breakers) from high voltages, so that the equipment can be maintained.
Any test equipment that your life may depend on when using it must first be tested before being used. These types of test equipment usually have internal apparatus that can verify that the equipment is working perfectly before it is used by personnel. Linesmen use this type of test equipment before working on primary voltage lines.
Any test equipment that your life may depend on when using it must first be tested before being used. These types of test equipment usually have internal apparatus that can verify that the equipment is working perfectly before it is used by personnel. Linesmen use this type of test equipment before working on primary voltage lines.
Yes, the electrical code states that all electrical equipment must be grounded.
Answer for USA, Canada and countries running a 60 Hertz supply service.The electrical code states that all electrical equipment must be grounded.
Must be tested by animals first.
Depends on the type of EED and the test instrument. With a current limited test instrument and a reasonably high power EED continuity can be tested. But with a regular instrument and sensitive EEDs it's best to disconnect them.
True.
The National Electrical Code is the recognised standard to which all electrical wiring and installations must adhere to. It is a requirement of selling a house that all wiring and equipment must feature this code to prove it has been correctly fitted.
Electrical Engineers require a degree from an accredited university if they wish to have a fruitful career. Hopeful electrical engineers must be great problem solvers and reasoners. The knowledge of current and future equipment and technology is an absolute must. Electrical Engineers must also have a strong knowledge of mathematics and the sciences, as well as their applications. http://jobs.virginia.gov/careerguides/electricalengineers.htm
if the shock crosses the equipment then yes. it must also be a large shock
electrical PVC is not bar pressure tested and is therefore quite thin and does not contain certain chemicles in the pipe to stop water corrosion where as plumbing PVC pipes are tested and generally thicker and must be in order to prevent burst pipes and pressure spikes
You must read first the instructions in the manual before operating the new equipment to avoid errors.