Incomplete data: To have an accurate result - please provide the following;
1. Voltage Rating - Low Votage or Medium Voltage Applications?
2. Efficiency
3. Power Factor
4. Distance - One way distance from source
5. Location and method and arrangement of Installation
6. Allowable or acceptable voltage drop
7. Type of cable - PVC or XLPE cable with same size has different ampacity
what is the size of wire has to use for 25kw 3phase motor
16mm
8mm
It depends on the power rating of the circuit but a common size would be 95 sq. mm up to about twice that. 11 kV systems are usually 3-phase 3-wire. Underground cables use copper while overhead ones tend to use uninsulated aluminium or aluminium conductor steel reinforced (ACSR) cables.
65 meg ohm if it is 11 kv
12 Lead, Single Voltage, Wye Start - Delta Run. Wye start; L1 to 1 and 7. L2 to 2 and 8. L3 to 3 and 9. All joined together 6,12,4,10,5 and 11. Delta run; L1 to 1, 6, 7, and 12. L2 to 2, 4, 8, and 10. L3 to 3, 5, 9, and 11. To reverse the direction of the motor interchange L1 and L2 of the supply voltage.
Postcode for Kidderminster in the West Midlands, UK. Also a vector group (connection configuration) of a 3-phase transformer.D - Means Delta Wound Primary Y - Means Wye (Star) Wound Secondary 11 - Is the phase shift between the two windings. The 11 refers to 11 on a clock face, hence 30 degrees.
In order to answer this question, you need to know (a) its efficiency, and (b) its power factor at full load. 11 kW (not 'Kw') is its output power, so you need to know its efficiency in order to determine its input power. Then, because, for a three-phase system, power is equal to 1.732 times the product of the line voltage, line current, and power factor, you also need to know its power factor.
Assuming it is a 400 V three-phase motor, the phase current is 11 amps, or more if the power factor is less than 1.0 (or the supply voltage is different). If it is a 400 V motor the cable should be capable of carrying 16 amps, so a 2.5 mm-sq 4-core cable is needed.
Yes, most large motors are three phase. Usually single phase motors only go up to 10 HP. Larger than this and the wire size and contactors used to control the motors becomes extreme. For example a single phase 10 HP motor on 115 volts draws 100 amps. The same single phase motor on 230 volts draws 50 amps. The same 10 HP motor on three phase system draws the following amperage; 230 volts is a 28 amp draw, 460 volts is a 14 amp draw and 575 volts is a 11 amp draw. As you can see the higher the voltage becomes, the smaller the wire feeder size is needed and much smaller size contactor can be used to control the motor.
The electrical code states that a 7.5 HP 460 volt three phase motor draws 11 amps. For fuse sizes, non time delay - 30 amps, time delay type D - 20 amps and if using a breaker it will be 30 amps. Minimum wire size is #12 and the maximum setting of overload devices will be 13.75 amps
To calculate kWh a time component is needed for the hours.
It depends on the power rating of the circuit but a common size would be 95 sq. mm up to about twice that. 11 kV systems are usually 3-phase 3-wire. Underground cables use copper while overhead ones tend to use uninsulated aluminium or aluminium conductor steel reinforced (ACSR) cables.
It depends on the design of the transformer but 1 MVA is a common size for an 11 kV / 415 v three-phase transformer.
75 HP = 55 KW 55 = 31/2 x 0.220 x I x cos φ = 31/2 x 0.220 x 0.8 x I I = 55/(31/2 x 0.220 x 0.8) = 180,42 A 3 x 70 mm2 is the size of cable for 75 HP 220 Volts 3 phase motor
It's the coax cable used for Thick Ethernet.
Tommy Cable was born on 1900-11-27.
127 mm for Indoor
officially a 15hp engine max. But, if you take a old 2 strokes, you can put more.
Yes. RG-11 is 75 ohm cable much the same as any other cable like RG-59, RG-6 or RG-56.