I assume you are asking about an inverter that uses a 12V battery to supply 120VAC. If so, depending on the efficiency of your inverter, the battery current will be around 130 to 140 amps at full load. For that current, the smallest cable you would want to use is 2/0 (two-ought). If your cable length is over 5 or 6 feet you would want even larger cable, perhaps 4/0 to minimize voltage drop. Make or have made the proper crimp lug terminations at each end of the cable. Do not scrimp here! Improperly made connections will generate heat, and could ruin the equipment or even start a fire. If the wiring runs through a vehicle chassis, then be sure to install a fuse at the battery! If cables this size were to wear through on a sharp metal edge and short together, there will be more than enough heat generated to start a fire. Be safe!
35 KVA generator using for load 100 meter length which cable need to used
To calculate the cable size for a 1500 mm length, you need to consider factors such as the load current, voltage drop, and the type of insulation material. First, determine the current carrying capacity required based on the load. Then, use a voltage drop formula to ensure the drop is within acceptable limits, typically around 3-5% of the supply voltage. Consult cable sizing charts or standards that provide guidance based on these parameters to select the appropriate cable size.
Yes. 1500 mA = 1.5 A
The cost of installing 10 power points in a brick wall can vary depending on several factors such as the location of the wall, accessibility to electrical wiring, and the complexity of the installation. On average, the cost can range from $500 to $1500 per power point. This estimate includes materials, labor, and any additional fees for permits or specialized equipment. It is recommended to get quotes from licensed electricians to get a more accurate cost for your specific project.
Potential Difference across a resistor is given by, Potential Difference = Resistance * Current = 1500 * 0.075 = 112.5 Volts
Catalytic Converter is clogged.
Disconnect the positive cable at the 95 1500 battery. Follow the cable to the other end and look at how it was routed. Unhook the cable end and pull it out. Route the new cable in the same way. Connect the cable ends back up.
No, a 1500-watt power converter is not suitable for a 5 amp freezer. To determine compatibility, use the formula: Watts = Volts x Amps. In this case, 5 amps x 120 volts (standard in the US) equals 600 watts, so a 1500-watt converter would be excessive and potentially dangerous for a 5 amp freezer.
No!
How to replace o2 pre converter gmc 1500
Underneath the 1995 Chevy 1500, the cables from the real wheels connect to the cable from the brake pedal. The connection has an adjustment bolt that when tightened will make the brakes tighter.
The torque converter is between the engine and transmission
The upstream is screwed into the front of the catalytic converter, while the downstream is screwed into the pipe after the converter.
might have a clogged catalytic converter. does your convertor get red hot? and if so then your may convertor may have melted the inside. This is not that uncommon and it will cause the truck to be doggy and no power. Check this and see what you fond.
There are two. The upstream is screwed into the front of the catalytic converter. The downstream is in the pipe after the catalytic converter.
how do you change the speedo cable on a 99 goldwing 1500, and how do you lube the front end/ I need instructions, not parts
The rates change every day. Use this currency converter to calculate it.