Ideally megger test is the best test used to check the resistance of motor winding.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Electrical Engineering

Why you do insulation resistance test?

in order to avoid unwanted short circuit break downs.... short circuit can burn the transformer and motor winding.... Megger is the device used to check the insulation .


What will happen to the transformer if rated voltage is applied to the winding during short circuit test?

If rated voltage is applied to Transformer during S/C test, The secondary winding will burn out due ta heavy current flow through the winding. During S/C test the secondary winding is short circuited so the impedance between phase and neutral is very low(only winding resistance). But the voltage across the secondary winding is rated hence heavy current flows through the winding, as I=V/Z. it depends which rated voltage is applied. if you are talking about primary winding voltage, transformer should withstand the primary rated voltage it's been designed for (OR it has been poorly designed). Otherwise, if rated voltage is the insulation voltage between a winding and earth OR winding-to-winding, you just have to check if: 1 - it is higher than the maximum primary winding voltage the transformer can withstand (could be, could not be..). Then, you can guess if your transformer is likely to burn or not. 2 - your test setup (usually a HV generator connected between primary and secondary winding) can deliver the requested current for the setup. I guess this won't be the case, since HV testers are usually designed to generate high voltages, but very small output currents.


What is meggers?

A megger is an electrical instrument that is used to measure the resistance of insulation by applying a DC voltage to the conductor. One lead is connected to the conductor and the other lead is connected to ground. Safe insulation reading to ground should be above 2,000,000 ohms or 2 megs.


How do you check single phase motor winding?

Single phase motor winding is often checked just by listening to the noise that the motor is making. An experienced person can tell if the motor is working at single phase or double phase.


How do you check 110volt motor for short?

To check any piece of electrical equipment for a short circuit a megohm meter will be used. The common name for this piece of equipment is a megger.

Related Questions

How can you check the motor's windings whether short circuit?

To check a motor's windings for a short circuit, you can use a multimeter to measure the resistance between the winding terminals. A reading close to zero ohms indicates a short circuit, while an infinite or very high resistance suggests the windings are intact. Additionally, you can check for shorts between the windings and the motor frame by measuring resistance from the winding terminals to the frame; any low resistance reading indicates a short to ground. Always ensure the motor is powered off and disconnected before performing these tests for safety.


How do you check a motor for a bad winding?

You need a Megger tester. With one lead attached to the winding and the other attached to the motor housing, the Megger sends a high voltage through the winding. The Megger reads the resistance, letting you know if there is a short to ground.


What should you do to locate the shorted point in the starting winding?

To locate the shorted point in the starting winding of a motor, first, disconnect the power supply and use a multimeter to check for continuity in the winding. Measure the resistance across the winding; a significantly lower resistance indicates a short. If a short is suspected, you can also perform a visual inspection for any burnt or damaged insulation. Finally, if necessary, isolate individual turns of the winding to pinpoint the exact location of the short.


Can you check ignition coil with ohms meter?

Yes, you can check an ignition coil with an ohmmeter by measuring its primary and secondary windings' resistance. For the primary winding, connect the ohmmeter leads to the terminals and check for resistance, which typically ranges from 0.5 to 2 ohms. For the secondary winding, connect one lead to the high-voltage terminal and the other to the primary terminal, expecting a resistance reading in the range of several thousand ohms, depending on the coil specifications. If the readings are significantly outside these ranges, the ignition coil may be faulty.


What electrical test instrument is used to measure continuity in a compressor winding?

A digital multimeter (DMM) is commonly used to measure continuity in a compressor winding. By setting the multimeter to the continuity test mode, it can check for a complete electrical path in the winding. If the circuit is intact, the multimeter will emit a beep or display a low resistance value, indicating good continuity. This test helps identify any open circuits or faults in the winding.


Why you do insulation resistance test?

in order to avoid unwanted short circuit break downs.... short circuit can burn the transformer and motor winding.... Megger is the device used to check the insulation .


What are the resistance specifications for a coil on a 1990 Mazda 929 S?

The resistance specifications for the ignition coil on a 1990 Mazda 929 S typically range from 0.5 to 1.0 ohms for the primary winding and 8,000 to 12,000 ohms for the secondary winding. It's important to check these values with a multimeter to ensure the coil is functioning properly. Always refer to the vehicle's service manual for precise specifications and testing procedures.


What will happen to the transformer if rated voltage is applied to the winding during short circuit test?

If rated voltage is applied to Transformer during S/C test, The secondary winding will burn out due ta heavy current flow through the winding. During S/C test the secondary winding is short circuited so the impedance between phase and neutral is very low(only winding resistance). But the voltage across the secondary winding is rated hence heavy current flows through the winding, as I=V/Z. it depends which rated voltage is applied. if you are talking about primary winding voltage, transformer should withstand the primary rated voltage it's been designed for (OR it has been poorly designed). Otherwise, if rated voltage is the insulation voltage between a winding and earth OR winding-to-winding, you just have to check if: 1 - it is higher than the maximum primary winding voltage the transformer can withstand (could be, could not be..). Then, you can guess if your transformer is likely to burn or not. 2 - your test setup (usually a HV generator connected between primary and secondary winding) can deliver the requested current for the setup. I guess this won't be the case, since HV testers are usually designed to generate high voltages, but very small output currents.


How do you test a dimmer switch with a multimeter?

You cannot use an ordinary multimeter to assess the difference between a normal power transformer winding and a shorted power transformer winding. You need a Q meter and/or to power it up at a reduced voltage with limited current to see what happens. Note that a shorted power transformer is capable of exploding, so you need to take appropriate safety precautions.


How do you know if a three phase motor's winding is shorted?

You use a megger. This allows you to check what the condition of the insulation of the motor windings are. An ohms check on each phase should be an easy way if it reads OPEN then there's your bad phase. Otherwise there are diffrent types of 3 phase motors, could be the brushes, commutator, sliprings, many many things.


How do you check mega ohms on compressor?

Usually you check mega-ohms by reading the resistance between compressor shell and the windings. There should be a large amount of resistance which means the windings are not shorted to the compressor case or shell. Use a DVM (digital volt ohm meter) to check the resistance.


What is the difference between continuity and resistance check?

Continuity check tests if there is a complete path for electricity to flow between two points, indicating if there is a break in the circuit. Resistance check measures the opposition to the flow of electricity in a circuit, providing information about the quality of connections or components.