It depends which side of the motor you are looking at!
The direction of a singular phase induction ac motor can be reversed by switching the capacitor in relation with the motor windings. When started in the reverse direction, the motor will maintain the same torque level that it had in the forward direction.
A single phase induction motor is not self starting; thus, it is necessary to provide a starting circuit and associated start windings to give the initial rotation in a single phase induction motor. The normal running windings within such a motor can cause the rotor to turn in either direction, so the starting circuit determines the operating direction.
The single phase induction motors are made self starting by providing an additional flux by some additional means. Now depending upon these additional means the single phase induction motors are classified as: 1.Split phase induction motor. 2.Capacitor start inductor motor. 3.Capacitor start capacitor run induction motor. 4. Shaded pole induction motor.
why three phase induction motor is delta connected
A two-phase* system is archaic, and has been completely superceded by three-phase systems, so there is no demand for two-phase induction motors. (*A two-phase generator has two phase windings, displaced from each other by 90 degrees.)
The direction of a singular phase induction ac motor can be reversed by switching the capacitor in relation with the motor windings. When started in the reverse direction, the motor will maintain the same torque level that it had in the forward direction.
A three-phase induction motor can reverse direction of travel by swapping any two of the three input phases. This changes the rotating magnetic field direction, causing the motor to rotate in the opposite direction. No change to the input phase sequence is required.
A single phase induction motor has two sets of coils and a centrifugal start switch. The start winding is in series with the start switch. The start winding provides a rotating magnetic field in one direction enabling the motor to start. The motor can be reversed by reversing the connections of either the start winding or the run winding but not both.
Swap any two phase connections. You may need to adjust the starting connections/mechanism as well.
A single phase induction motor is not self starting; thus, it is necessary to provide a starting circuit and associated start windings to give the initial rotation in a single phase induction motor. The normal running windings within such a motor can cause the rotor to turn in either direction, so the starting circuit determines the operating direction.
Split Phase Induction Motor.
the motor keep on running for a while but the current will rise on the two other
No, commutator motors as used in vaccum cleaners for example do not use a starting winding. Single-phase induction motors need a starting winding without which they will start in either direction if given an initial twist.
That indicates a fault in the induction motor.
Yes, that is one of the major advantages of a three-phase induction motor.
how reversing an ac single phase induction motor to wark as induction generator
One of the disadvantages of the 3 phase induction motor is that it requires a three wire supply. The other disadvantage is that the 3 phase induction motors have poor starting torque and high have in the rush currents.