Air-blast circuit breakers are used to disconnect high-voltage transmission or distribution circuits in the event of a fault. One circuit breaker is required for each of the three line conductors; there is not normally a neutral conductor in high-voltage three-phase transmission/distribution lines.
"Air" and "Vacuum" describe how the breaker extinguishes the arcing current. An Air breaker opens far enough that the dielectric strenght of air is enough to extinguish the arc. A vacuum breaker's contacts are in a vacuum. Oil breakers use oil. SF6 breakers use SF6 gas to extinguish the arc.
SION Vacuum Circuit-Breaker
VCB is Vacuum Circuit Breaker. It is one of the type of Circuit breaker. In VCB arching chamber is vacuum instead of oil or such arc quenching media. Its function is to break the circuit automatically in case of fault or to isolate the circuit under normal situation also.
The VCB yard us basically a yard that uses the Vacuum Circuit Breaker.
In VCB, The two contacts are present in a vaccum, When there is a fault these contacts are forced to open resulting arch ,as all we know arch does not flow through Vaccum so it extinguishes thus vcb seperates two circuits.
acb means AIR CIRCUIT BREAKER ,& vcb means VACUUM CIRCUIT BREAKER
"Air" and "Vacuum" describe how the breaker extinguishes the arcing current. An Air breaker opens far enough that the dielectric strenght of air is enough to extinguish the arc. A vacuum breaker's contacts are in a vacuum. Oil breakers use oil. SF6 breakers use SF6 gas to extinguish the arc.
A vacuum circuit breaker is a high-voltage circuit breaker whose contacts separate within a vacuum dielectric. The vacuum contributes to extinguishing the resulting arc because ionisation cannot take place while the arc is stretched between the separating contacts.
SION Vacuum Circuit-Breaker
In a vacuum breaker the moving contact and fixed contact are sealed inside a vacuum chamber. Electrons cannot flow in a vacuum, therefore as soon as the moving contact seperates from the fixed contact the arc meets an infinite resistance and is immediately extinguished. Because of this, the gap between the fixed and moving contacts when the breaker is open need only be a tiny amount.
By means of Megger Vidar or Vanguad VBT Series
vcb is have vaccume and sf6 cb is filled with sf6 gas which will have good arc quencing property
VCB is Vacuum Circuit Breaker. It is one of the type of Circuit breaker. In VCB arching chamber is vacuum instead of oil or such arc quenching media. Its function is to break the circuit automatically in case of fault or to isolate the circuit under normal situation also.
A circuit breaker is a switching device which can make,brake and carrying (or trip the circuit) that specified over currents for a small interval of time . There is a different types of Circuit Breaker's are there 1.According to their arc quenching media these are divided into 4 types a) Oil circuit breaker b) Air blast circuit breaker c) SF6 circuit breaker d) vacuum circuit breaker 2. According to their services the circuit breaker can be divided as a) Outdoor Circuit Breaker b) Indoor Breaker 3. According to the operating mechanism of circuit breaker they can be divided as a) Spring operated Circuit Breaker b) Pneumatic Circuit Breaker c) Hydrolic Circuit Breaker 4. According to the voltage level of installation these are divided into 3 types a) High Voltage Circuit Breaker b) Medium Voltage Circuit Breaker c) Low Voltage Circuit Breaker.
Vacuum circuit breaker is used in railway applications and as it is used in the applications where current chopping phenomenon is more
The VCB yard us basically a yard that uses the Vacuum Circuit Breaker.
7.3 ohms