The differential producing flowmeter or Venturi has a long history of uses in many applications. Due to its simplicity and dependability, the Venturi is among the most common flowmeters. With no moving parts or abrupt flow restrictions, the Venturi can measure fluid flowrates with a minimal total pressure loss.

The principle behind the operation of the Venturi flowmeter is the Bernoulli effect. The Venturi measures a fluid's flowrate by reducing the cross sectional flow area in the flow path and generating a pressure difference. After the pressure difference is generated, the fluid is passed through a pressure recovery exit section where up to 80% of the differential pressure generated at the throat is recovered. The pressure differential follows Bernoulli's Equation.

Bernoulli's Equation:

The Venturi Principle

In the illustration above, the fluid, either liquid or gaseous, enters the Venturi at the location with a cross-sectional area A1, pressure P1, and velocity v1. These properties form the potential and kinetic energy of the fluid at one location. Energy is conserved in a closed system, that is, the sum of potential and kinetic energy at one location must equal the sum of the potential and kinetic energy at any another location in the system. If potential energy decreases at one location, the kinetic energy must proportionally increase at that location. The fluid now enters the throat of the Venturi with a new area A2, which is smaller than A1. In a closed system mass can be neither created nor destroyed (law of conservation of mass, simply, what goes in, must come out), and as such, the volumetric flowrate at area A1 must equal the volumetric flowrate at area A2. If the area at location A2 is smaller than A1, the fluid must travel faster to maintain the same volumetric flowrate. This increase in velocity results in a decrease in pressure which follows Bernoulli's equation. The result: by knowing the pressure and cross-sectional area at two locations, one can calculate the velocity of the fluid. With the velocity of the fluid and its density, one can calculate the flowrate.

A Venturi requires two pressure and one temperature measurement to accurately determine flow. The first pressure is measured at the Venturi's upstream location, P1. This is used for the density calculation and the high side input to the differential pressure measurement.

The Venturi Flowmeter

The second pressure is measured at the Venturi's throat, P2. This is connected to the low side of the differential pressure gauge to form the DP pressure measurement. The temperature reading is taken several pipe diameters in length upstream of the Venturi so as not to disrupt the uniform flow profile.

With proper instrumentation and flow conditioning, a Venturi's flowrate can be reduced to about 10% of its full scale range without adding multiple transducer configurations. This provides a 10 to 1 turn-down in a Venturi's flow range, For example: If a Venturi is designed for a maximum flow of 50 SCFM, approximately 5 SCFM would be the lowest value readable but there are compromises. See Instrumentation for a detailed discussion on instrumenting venturi flowmeters and how to maximize the measurement accuracy.

Applications:

Installation Requirements for Venturi Flowmeters:

1) 10-20 diameters in length of straight pipe upstream of the Venturi

2) 5 diameters in length of straight pipe downstream of the Venturi

3) Flow conditioning tube before the Venturi, if the flow is non-uniform or swirling

Free Flow System This arrangement is probably the most common, allowing the Venturi to be installed at any point within the flowing system. The location is generally selected for installation convenience and best flow conditioning. Flow conditioning is necessary to minimize swirling and non-uniform flow profiles such as patterns created by fittings, regulators, and any other flow affecting devices.

Pressure Reducing Flow System A Venturi can be installed at several different locations within a pressure reducing flow system. Each location generally has advantages and disadvantages. In the diagram below, two locations are shown for the Venturi's location. Location A is in the high pressure supply line to the system. Location B is after the pressure regulator has substantially reduced the flowing pressure and density. Because of the higher gas density at location A, the Venturi will have a greater flow range than at the lower pressure location B. However, this greater range comes at the cost of lower signal resolution as compared with location B. This would be similar to measuring the accuracy of a clock by timing either the minute hand or the second hand. Both clock hands carry the same accuracy information, the timing of the clock, but it would be much easier to measure the movement of the second hand versus the movement of the minute hand over a small time period. This is because the second hand has higher resolution, that is, it's easier to see a change in movement of the second hand versus a change in movement of the minute hand. If a greater time range is required, then one would need to measure the minute hand. It is the same with the Venturi's location. Some flow systems may only operate over a relatively small range. In that case, location B would be more advantageous than location A, and a properly sized Venturi at that location would provide the best signal resolution and accuracy. However, if measuring the full flow range of the system is required, then location A is the proper configuration. It is tempting to size a Venturi to measure the full air supply flow range, but, if it is only operated over a small flow range, this wide range comes at the cost of lower signal resolution and lower measurement accuracy. Require the Venturi to measure only the range that you need.

Free Standing Inlet System A Venturi can be installed as the inlet component to a flow system. This arrangement is often used as a calibration standard for a CVS (Constant Volume System) flow stand in emissions testing. Venturis used in this application are referred to as SAOs (Smooth Approach Orifice). SAOs have several advantages over LFEs (Laminar Flow Elements), also used in this application. SAOs are calibrated to an accuracy level which is expressed in percent of reading. LFEs are calibrated typically to percent of full scale. This is very advantageous at mid range and lower flow rates, the error being a percent of reading not of full scale. As with Sonic Nozzles, Venturis (SAOs) will retain their original calibration accuracy unless they are physically damaged or abused. The stainless steel or anodized aluminum surface will not erode through normal everyday use with clean air.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

According to the "Engineering Tool Box" website (refer to the link, below), "The orifice, nozzle and venturi flow rate meters use the Bernoulli Equation to calculate the fluid flow rate using pressure difference through obstructions in the flow."

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Working principle of venturi meter
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is Working principle of venturi tube?

Venturi tube is used to for flow measurement. It work on the principle of Bernoulli Equation.


What is the principle of venturi mask?

bernoulli principle


What is venturi meter?

Measuring flow of a fluid based on Bernoulli's principle.


What is the working principle of a q-meter?

Q-meter works on the principle of Series Resonance


Fluid mechanics in venturi meter?

Venturi Meter is a device used for measuring the flow of the fluid.


What is the Working principle of taung tester clamp meter?

CLAMP METER WORKS WITH THE PRINCIPLE OF HALL EFFECT..


How accurate is a venturi meter?

9


Working principle of energy meter?

http://en.wikipedia.org/wiki/Electricity_meter


Why is coefficient of discharge of venturi meter is more than coefficient of discharge of orifice meter?

In Venturi meter losses are less so coefficient of discharge is higher whereas in orifice meter due to no convergent and divergent cones there are more losses and hence its coefficient of discharge is less.In venturi meter losses are low due to steamline shape of the diffuser and the pressure gradient is not abrupt as in case of orifice meter.


What is the principle on which carburettor works?

The basic principle is the carb holds gas in a float bowl with an exit needle to the venturi. When this exit needle is opened by pressing the accelarator, the air valve at top of venturi also opens, thus mixing air and gas in the venturi and admitting the mixture into the intake manifold.


Tell me the main uses of venturi meter?

The discharge coefficient is near unity and Non-recoverable net head loss is very small.


What is the order of efficiency of venturi meter orifice meter and rotoameter?

The orifice plate can easily be changed to accomodate widely different flow rates, whereas the throat diameter of a venturi is fixed, so that its range of flow rates is circumscribed by the practical limits of Dp.The orifice meter has a large permanent loss of pressure because of the presence of eddies on the downstream side of the orifice-plate; the shape of the venturi meter prevents the formation OS these eddies and greatly reduces the permanent loss.The orifice is cheap and easy to install. The venturi meter is expensive, as it must be carefully proportioned and fabricated. A home made orifice is often entirely satisfactory, whereas a venturi meter is practically always purchased from an instrument dealer.On the other hand, the head lost in the orifice for the same conditions as in the venturi is many times greater. The power lost is proportionally greater, and, when an orifice is inserted in a line carrying fluid continuously over long periods of time, the cost of the power may be out of all proportion to the saving in first cost. Orifices are therefore best used for testing purposes or other cases where the power lost is not a factor, as in steam lines.However, in spite of considerations of power loss, orifices are widely used, partly because of their greater flexibility, because installing a new orifice plate with a different opening is a simpler matter. The venturi meter can not be so altered. Venturi meters are used only for permanent installations.It should be noted that for a given pipe diameter and a given diameter of orifice opening or venturi throat, the reading of the venturi meter for a given velocity is to the reading of the orifice as (0.61/0.98)2, or 1:2.58.(i.e. orifice meter will show higher manometer reading for a given velocity than venturi meter).