Yes, L1 of the single phase supply is terminated under terminal L1 of the three phase contactor. L2 of the single phase supply is terminated under terminal L2 of the three phase contactor. A conductor from output terminal T2 is then taken to input terminal L3. The single phase load is then connected to the contactor's output terminals T1 and T3. This incorporates all three of the overload blocks on the contactor into the control circuit. With the overloads in the control circuit, if an overload occurs the magnetic contactor's holding coil will drop out and take the load off line.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

Can you replace an 3 phase solid state relay with a contactor on a 3 phase heater?

Not without other modifications. The circuits used to turn the solid state relay on will not be suitable for turning a contactor on.


Do they make 3 phase oven for home use?

Three phase ovens are made for home use. It is important however to know if the home is wired for three phase or for single phase.


You found a 220volt coil on a 3 phase motor contactor and the one side of the coil is feed from B phase and the other side is also feed from B phase it would not pull in the contactor?

your not completing the circuit your only using one phase for a three phase motor


What causes a contactor for a 3 phase motor to kick in and out. Tha contactor was replaced with the heaters and still kicks in amd out?

See discuss question below.


How do you use a 3 phase contactor in a single phase installation?

A CONTACTOR SHOULD NOT BE USED TO START A 3-PHASE MOTOR unless there is some sort of motor protection in series with it. You would need a 3-phase contactor and just connect each phase (1 wire) to each terminal of the line side of the contactor, and the 3 wires to the load side. 3 wires on the line side, and 3 wires on the load side.


Does a 2 horsepower rotary converter plug into 120 single phase and convert it to plug in a 3 phase outlet?

All my experience with rotary phase converters have been in converting 240 volt single phase into 240 volt three phase. They all were hard wired into their respective systems, so my answer is no.


How do you tell if a 3 phase contactor is bad?

To determine if a 3-phase contactor is bad, you can check for physical signs of damage such as burnt contacts or melted components. Use a multimeter to test continuity across the contact terminals; if there is no continuity when the coil is energized, the contactor may be faulty. Additionally, listen for unusual noises when the contactor operates and check for overheating, which can indicate internal issues. If the contactor fails to engage or disengage properly, it is likely bad and should be replaced.


How do you convert a 3-phase system to a single phase?

By having a transformer with 3 phase input and single phase out put


How do you derive three phase single way?

3 phase /sqrt(3) * 30 degree phase shift = single phase.


How do you connected 3 phase motor to single phase power?

Use VFD to make 3 phase from single phase source.


Are contactor points and bimetallic strip connected to the star delta starter of 3 phase induction motor?

yes


How does 120Volts single phase convert to 220Volts 3 phase when the 3 phase voltage should be 208Volts ie 120V x sq route of 3 equals 208V?

If you get 220 volts instead of 208 volts it means that the transformer supplying the circuit is wired in Delta with one of the legs center-tapped to ground.