Can you do it - yes. SHOULD you do it - NO. Because brass and galvanized conduit have different electrochemical potentials (go talk to a chemistry teacher if you need an explanation of electrochemical potential) if you place them in direct contact with each other, you will set up a galvanic differential and promote corrosion. If you must connect brass and galvanized conduit, you should use a connector between the two that will isolate them electrically from each other. In essence, you are "insulating" them from each other so that you don't get an electric current between them to promote corrosion. There are special fittings, I believe they are referred to as "dielectric fittings" that are designed to provide this insulation and avoid the problem of galvanic corrosion. The more corrosive the liquid you have in the pipes, the more important it is to use these special fittings. Hard or salty water can particularly problematic.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

What is the imc wiring method?

intermediate galvanized conduit


What is imc wiring method?

intermediate galvanized conduit


What is galvanized conduit coated with?

does anyone know this answer does anyone know this answer


What is Galvanized rigid conduit is coated with?

Galvanized rigid conduit is coated with a layer of zinc to provide protection against corrosion. This coating helps to extend the lifespan of the conduit when used in outdoor or corrosive environments.


Can you use brass and galvanized pipe for a gas line?

No.


Is it okay to connect copper pipe to brass to galvanized to brass and back to copper or will it cause a reaction that will corrode the pipes?

If you do connect copper pipe to galvanized pipe, you will need a dielectric coupling or else the galvanized pipe will corrode. Same with connecting galvanized pipe to brass fittings. Brass is an alloy that contains copper and therefore the same electrolytic properties will exist unless a dielectric coupling is used. Hope that helps you out.


Can you transition from a female brass fitting to galvanized or must you use a dilectric?

It is recommended to use a dielectric union when transitioning from a female brass fitting to galvanized steel to prevent corrosion due to the dissimilar metals. This helps to avoid galvanic corrosion that can occur when directly connecting brass and galvanized steel fittings.


Can you connect copper to galvanized by using a bronze fitting?

Yes! The best copper-to-galvanized connection is made using a brass nipple in between the two dissimilar metals. The nipple should be a minimum of 2 1/2" long (preferably six inches long). Bronze is an alloy (copper + tin). Brass is an alloy (copper + zinc).


How do you remove a brass fitting from a galvanized fitting?

Two pipe wrenches. One to hold the galvanized from turning and one to turn the brass fitting. Pull on one and push on the other and it should come out.


Which metal is used to make water pipes in houses?

Copper, Brass, Yellow Brass , Red Brass, Galvainzed steel, Galvanized wrought , Yalloy


Can galvanized conduit be chrome plated?

Simply put, no. The long answer: The process of chrome plating involves the chromium actually bonding to the metal substrate through an entergetic reaction. Galvanizing metal introduces a layer of zinc oxide into the mix which would contaminate the plating process. The chrome would actually split bond to the zinc and possibly somewhat to the substrate. This would cause the zinc to lose its bond with the metal substrate. If it all stayed intact the part would, at first, appear to be chrome plated, but due to the zinc oxide contamination it will flake off easily. I hope this is a sufficient answer to your query.


Can brass be galvanized?

IT IS PART Galvanized don't you knowGalvanized is ZINC coating on black steel and YELLOW BRASS piping is 40% ZINC and 60% Copper and RED BRASS is 85% Copper and 15% Zinc=The problem with TOO much Zinc content is dezincification where the piping becomes brittle and to little zinc and the brass is too soft as the higher copper content.==Mixing Galvanized steel and brass or copper causes a condition of electrolytic action as your mixing ferrous metals and non ferrous metals. ( this is first year apprentice training) to prevent the electrolysis one should use a dielectric fitting=