Hi,

24 volt control Transformers come in all kinds of sizes and voltage options.

If you have a all electric system then chances are you have 230 volt A.C. primary to 24 V.A.C. secondary.

If you have a gas system I'm assuming 120 volt A.C. primary to 24 V.A.C. secondary output transformer.

The above two are in no case all there are out there but the most common in the H.V.A.C. field.

These small control transformers are typically rated in VA ratings.

Make sure your transformer is showing its full voltage potential reading under full load on the output 24volt A.C. side. If it is not , then you either have a transformer that is to small from some addition to your system or wrong transformer replacement in past. You can check the amperage output with a amproble if necessary on secondary side. It should not go above the name plate rating. If it does, check to see if your equipments literature or supplier & manufacture can tell you what original equipment was designed for this system.

Sometimes the transformer will hum when under heavy load. Whatever part of the system that started drawing power when this occurse is usually your culprit to your problem.

Transformers can just age and go bad. (OR just go bad period) if it hums alot then it has weakly wrapped windings which can cause insulation failure within the coil.

But please do remember most transformers get louder the closer they come to their nominal designed conditions.

Sometimes if your Amprobe will not pick up the small signal you can wrap a wire around the wire you are checking 10 times and connect at ends and it will magnify your reading x10 so you can see it on your amprobe.

Transformers usually really stink when they go down. They have a real sharp burned smell that stands out quiet strongly. So Use your nose.

Basically this is what you will see in most home situations:

central heat only=20 VA rating 24 volt transformer

central heat with cooling = 40 VA rating 24 volt transformer

Heat Pumps and dual fuel systems typically use =50va output ratings or sometimes 60 VA. because of all the extra devices they have to operate in the more complicated systems.

Remember any transformer should be seen and not heard if all is well.

Hope this helps: Jimiwane

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Engineering

How do you stop oil leakage in Transformer?

If you have a large power transformer that is leaking oil, do NOT touch it! Older transformer oil contains PCB's which are extremely toxic!! Get a licensed firm to test the oil for PCB's and repair or replace the transformer. Don't fool around with this! PCB's are a serious danger to you and others. Do not let this go. Get it fixed right away!


What is core type and sell type transformer?

Core transformer and shell transformer - it has a one window. - it has a two windows. - less mechanical protection - better mechanical protection to the coils. to the coils. -windings encircles the core. - core encircles the winding. - cylindrical windings are used. - sandwich type windings are used. - it is easy to repair. - it is not easy to repair.


Why would you use a three phase transformer in place of a single phase transformer?

the necesscity of two three phase transformers operating in parallel are as follows...if the one transformer fails to give supply,then another transformer can be used in parallel and hance,continuity of supply can be maintained.one transformer can be easily take out from the supply for repair & maintanance.if the load on the substation increases beyond the rated values of transformer, then another transformer can be used to share rhe load of the substation.


How do you repair the HV winding of casting resin power transformer dry type 1600 kVA 66042 kV insulation class 155 C degree?

what do you mean repair hv winding whats wrong with it


Can you connect a 24v dc motor to household current?

You need a DC power supply in order to connect a 24v DC motor to household power.

Related Questions

What is the recommended voltage requirement for a thermostat that is compatible with a 24V transformer?

The recommended voltage requirement for a thermostat compatible with a 24V transformer is 24 volts.


How do I wire a 24v transformer to a thermostat?

To wire a 24v transformer to a thermostat, connect the transformer's 24v hot wire to the thermostat's R terminal and the transformer's common wire to the thermostat's C terminal. Make sure to follow the manufacturer's instructions and turn off power before starting.


Can 24v 40va be used for24v 1 amp?

Yes, a 24V 40VA transformer can be used for a device that requires 24V 1A. The VA rating (volt-ampere) is a measure of the overall capacity of the transformer to deliver power, so the 40VA transformer has the capacity to supply the 1A required by the device.


What is the recommended voltage requirement for a doorbell system that is powered by a 24V doorbell transformer?

The recommended voltage requirement for a doorbell system powered by a 24V doorbell transformer is 24 volts.


If a 208V 24V transformer is humming with no voltage on the 24V side is it bad?

Of course it is bad, whether it`s humming or not.


What are the specifications and compatibility requirements for a 24V transformer plug-in?

A 24V transformer plug-in typically requires an input voltage of 120V AC and outputs 24V AC. It should be compatible with devices that require a 24V power supply. Make sure to check the wattage and current ratings to ensure compatibility with your device.


What is a 24v transformer used for?

A 24v transformer converts 120v to a lower voltage for use in push buttons, like doorbells, thermostats, gas valves, or air conditioning systems. They are an essential tool for electricians.


How do you convert 24volts to 12 volts?

If you want to convert 24v AC into 12v Ac, it's simple. Just get a transformer to convert 24 volts into 12 volts. This is called a stepdown transformer. If you want to convert 24v DC into 12v DC, it's more complicated. First you have to change the 24v DC into 24v AC by a switching converter that changes DC into AC. Then you would use a stepdown transformer as in the former example. Once the 24v AC is converted to 12v AC, then you use a rectifier bridge to change the 12v AC into 12v DC.


Why does my 120v 24v reduce to 28v. when you connect it to your boiler it blows out the transformer. is a problem with the transformer or the panel?

Please go to discuss question page.


What is the purpose of an HVAC transformer 24v in a heating and cooling system?

The purpose of an HVAC transformer 24v in a heating and cooling system is to convert the standard household voltage to a lower voltage that is safe for controlling the operation of the system's components, such as the thermostat, relays, and control boards.


Connecting a 240v to 24v 40va transformer?

To connect a 240V to 24V 40VA transformer, you will typically have two input wires for the 240V side and two output wires for the 24V side. The 240V input wires will connect to your power source, while the 24V output wires will connect to the device or circuit that requires the lower voltage. Make sure to follow proper wiring guidelines and safety precautions to avoid any electrical hazards.


What is the max secondary amperage for a 40VA 240x24 volt control transformer?

The secondary amperage for a 40VA control transformer with a 240V primary and 24V secondary voltage can be calculated using the formula Amps = VA / Voltage. In this case, the max secondary amperage would be 1.67A (40VA / 24V).