There are several type of circuit breakers now a day we are using these are as follows: 1. M.C.B. (Miniature circuit Breaker) Rating : 1, 2, 4, 6, 10, 16, 20, 25, 32, 63 Amperes 2. M.C.C.B. (Miniature current circuit Breaker) Rating : 10, 16, 20, 25, 32, 63, 100, 200, 250, 400 Amperes. 3. A.C.B. (Air Circuit Breaker) Rating : 400, 800, 1000, 1200, 1500, 1800, 2000 Amperes. 4. A. B. Switch (Air Breaker) used in High tension line. 5. SF6 Breaker (Contact break in the Sf6 medium) used in High tension line.
i had the same problem, sounded like the flasher was clicking. turns out it was the multi-function switch (turn signal/cruise ctrl/highbeam/washer switch). it was about 300 bucks to have replaced. couldn't do it myself.
Remember I = W/E
Current (amps)=Watts/Volts =2000/120 =16.75 =16.75 amps
I=U/R so 30/2000=0.015 so 15 mA
I need short circuit calculaion
The circuit breaker on a 2000 Ford Windstar is typically located in the fuse box under the hood or in the interior fuse panel. To test it, you can use a multimeter to check for continuity across the terminals. If there is no continuity or if the circuit breaker appears damaged, it may need to be replaced.
There are several type of circuit breakers now a day we are using these are as follows: 1. M.C.B. (Miniature circuit Breaker) Rating : 1, 2, 4, 6, 10, 16, 20, 25, 32, 63 Amperes 2. M.C.C.B. (Miniature current circuit Breaker) Rating : 10, 16, 20, 25, 32, 63, 100, 200, 250, 400 Amperes. 3. A.C.B. (Air Circuit Breaker) Rating : 400, 800, 1000, 1200, 1500, 1800, 2000 Amperes. 4. A. B. Switch (Air Breaker) used in High tension line. 5. SF6 Breaker (Contact break in the Sf6 medium) used in High tension line.
there is two 25 amp,is one located in each of the interior fuse/relay boxes at the ends of the dashboard
On a 2000 Chrysler Grand Voyager, the circuit breaker is typically located in the power distribution center (PDC) under the hood. The PDC is situated near the battery and contains fuses and circuit breakers for various electrical systems. Additionally, there may be some circuit breakers located inside the vehicle, often under the dashboard or behind the driver's side kick panel. Always refer to the owner’s manual for specific details and diagrams.
The formula to use is I = W/E, assuming that the single breaker is delivering 120 volts, the amperage to the circuit is 16.6 amps. A continuous load on a 20 amp breaker has to be reduced to 80% according to the electrical code. 20 x .8 = 16. So to answer the question, yes, a 20 amp breaker will support a 2000 watt load at 120 volts.
I think it is called the heater motor and has a circuit breaker and a 40 amp fuse in the under hood fuse compartment.
There are fancy testers that can be purchased that do just that. They are not very cost effective for anyone other than electricians that would use one every day, though. The poor man's method is simply to plug a lamp into the outlet and have someone watch it while you slowly turn off the breakers, one by one. Have your helper call out when the lamp goes out. Easy! Just make sure there are no critical appliances that would be harmed by being turned off, since you may happen to turn off anything in the house. If you happen to turn off the breaker supplying your wife's computer after she has spent an hour typing a report, you will see what I mean! You can also mentally eliminate some breakers without having to turn them off. If you are looking only for a standard receptacle circuit, you can eliminate all 2-pole breakers, since they feed 240 volt appliances, such as the stove, rooftop air conditioner, and electric water heater. Also, in the US, receptacles are almost always on a 15 or 20 amp breaker - start with those. The only time you will see a 120V recep. circuit that is more than 20A is when it feeds a specialized load - such as a large room AC, or an air compressor, or something like that.
A circuit breaker trips when the current exceeds the rated trip current. Usually the trip current should be at least 25% more than the maximum expected load current.
Use a breaker bar and appropriate sized socket Use a breaker bar and appropriate sized socket
You cannot safely plug a 2000 watt 240v appliance into a 120v 20 amp breaker without risking damage or fire hazard. To use the appliance, consider installing a step-up transformer to convert the voltage from 120v to 240v before plugging it in. This will ensure the appliance operates correctly without overloading the circuit.