If the generator is to maintain the same rpm and power output, then a heavier load will increase the diesel consumption.
The revolutions per minute the generator runs will increase as the load increases, thereby resulting in an increase in diesel consumption to maintain the high rpm.
A Generator has a governor which attempts to maintain frequency at 60 Hz for North America. For the generator to increase the power output at the same frequency, the governor will increase the fuel and air to the engine. The fuel consumption will not be linear because of the curves associated with the particular engine. The fuel to KWH is know as the heat rate curve for the generator.
An 80 kVA diesel generator typically consumes around 1 to 2 liters of fuel per hour when running under no load. This consumption can vary based on factors such as the generator's efficiency, maintenance condition, and specific model. However, it's important to note that fuel consumption is generally higher under load conditions. Always refer to the manufacturer's specifications for more accurate figures.
The diesel consumption of a 10KVA generator typically ranges from 0.25 to 0.5 liters per hour per KVA, depending on the load and efficiency. Assuming an average consumption of 0.3 liters per hour per KVA, running a 10KVA generator for 10 hours would require approximately 30 liters of diesel (0.3 liters/KVA/hour × 10 KVA × 10 hours). It's important to check the specific generator model for accurate fuel consumption rates.
To know how much fuel a 250KVA diesel generator uses per hour, referring to the operator's manual is all that is needed. It states that properly maintained diesel generators of this size average a fuel consumption of 21 gallons per hour.
with decrease in fuel consumption the amount of steam produced is also reduced.Hence when lower quantity of steam passes through the turbine the torque generated is less and since generator and turbine are coupled on a single shaft the generator torque also decrease which reduces load.
If you run out of diesel while operating a generator, the engine will stop running since it no longer has fuel to operate. This can lead to potential issues such as fuel system contamination or air entering the fuel lines, which may require bleeding the system to restart. It’s advisable to refill the tank promptly and follow the manufacturer's guidelines for restarting the generator to avoid damage.
1hrs diesel consumption with out load
0.3 l/kwh
300 kw power generate and fuel consumption
The fuel usage will be based on the load applied to the generator and how many KW the generator outputs. The more load the higher the fuel consumption. You do not list the output of the generator nor the load so all I do is point you to the diesel fuel generator consumption chart. Click the link to see the chart where you can figure it yourself.
10 litres
The fuel consumption of a 1250 kVA diesel generator at full load typically ranges from 200 to 250 liters per hour, depending on the generator's efficiency and the specific diesel engine model. Generally, a common estimation is that diesel generators consume about 0.25 to 0.3 liters of fuel per kWh produced. Therefore, the exact consumption can vary based on factors such as load characteristics and maintenance conditions.
The amount of diesel used in a diesel-powered generator depends on several factors including the generator's power output, fuel efficiency, and the duration of operation. Diesel generators typically have a fuel consumption rate measured in liters per hour (L/h) or gallons per hour (gal/h).To determine the specific amount of diesel used, you would need to know the generator's fuel consumption rate. This information can usually be found in the generator's specifications or user manual. For example, a small diesel generator with a 5-liter/hour fuel consumption rate would use 5 liters of diesel per hour of operation.
Diesel generator are generator that uses diesel. having the ability to withstand corrosive particles in fuel(diesel).
Dear Friends I'm also searching for this. How can i give the answer to you?
A 20 kVA generator typically consumes between 4 to 6 liters of fuel per hour, depending on its load, efficiency, and type of fuel used (diesel, petrol, etc.). At full load, the fuel consumption can be closer to the higher end of this range. It’s important to refer to the specific generator's manual for accurate consumption figures.
I have a new 80 kw diesel for sale
It's abaout 100 - 120 liter/hour, depend on load and efficiency characteristic of engine.