Yes, but only factory assembled units listed as such.
This would typically be seen in older residential installations where the service was of such a high amperage that the mains required larger breakers than were available (for that panel). Placing two breakers in parallel allowing sharing of the load. Two breakers per (split) phase would total four breakers. Two breakers of 50 amp rating each (in parallel) provide (generally) 100 amps of protection. Two sets of two would provide mains protection for a 200 amp service.
There are four types of circuit: series, parallel, series-parallel, and complex.
You do not build a series circuit in your home. The only series circuits are the circuits that go through circuit breakers, light switches, and relays. Electrical and electronic devices use internal series circuits but those are the only ones people build. No one builds series circuits for house wiring. Electrical outlets are connected with parallel wiring.
Switches used in electrical circuits are wired in series with either a parallel or series load. In parallel loads, the switch is upstream from the parallel circuit, so that the switch will shut off all of the parallel circuits.
parallel
The National Electrical Code (NEC) permits a minimum wire size of 14 AWG for general lighting and receptacle circuits in parallel installations.
AFCI (Arc Fault Circuit Interrupter) and CAFCI (Combination Arc Fault Circuit Interrupter) circuit breakers both protect against electrical fires caused by arcing faults. AFCIs detect parallel arcing faults, while CAFCIs detect both parallel and series arcing faults. These breakers help prevent fires by quickly shutting off power when they detect dangerous electrical arcs, reducing the risk of fire in residential buildings.
A voltmeter is connected in parallel in an electrical circuit.
This would typically be seen in older residential installations where the service was of such a high amperage that the mains required larger breakers than were available (for that panel). Placing two breakers in parallel allowing sharing of the load. Two breakers per (split) phase would total four breakers. Two breakers of 50 amp rating each (in parallel) provide (generally) 100 amps of protection. Two sets of two would provide mains protection for a 200 amp service.
In electrical engineering, shunt means 'parallel'.
constant electrical quantity-series connection -current constant electrical quantity-parallel connection - voltage
In a parallel circuit, each component is connected directly to the power source, resulting in multiple electrical paths. The number of electrical paths in a parallel circuit is equal to the number of components connected in parallel.
No. Plugs, lamps and 220 V a.c. items are in parallel with the breakers.CorrectionAll loads are in parallel with the supply voltage, but in series with the circuit breakers or fuses.
parallel
Connecting more appliances in parallel will increase the total current drawn from the power source, potentially causing an overload. This can lead to overheating of wires, tripping of circuit breakers, or damage to the appliances. It is important to ensure that the electrical system can handle the increased load and to distribute the load evenly across circuits.
Increasing the number of parallel circuits in an electrical system does not affect the voltage. Voltage remains constant across all parallel circuits in the system.
In the electrical trade there are three types of electrical circuits. They are series, parallel and series - parallel. All three types are used every day in building construction and home construction.