answersLogoWhite

0

I want to install 4 sets of generator with synchronising system. During main goes off, the first set will start and the subsequent sets will start upon demand of load. Likewise, when load requirement goes lower, genrastor will start stop on the basis of demand.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Engineering

Explain how load sharing of generator affected?

wala gne q kabalo


What are the advantages of automatic load sharing of transformers?

advantages for automatic load sharing of transformer with protective analysis


Why a rheostat is connected series to the load?

A rheostat is connected in series with a load to allow for the adjustment of current flowing through the load. By changing the resistance of the rheostat, the voltage across and the current through the load can be controlled, enabling fine-tuning of the load's performance. This configuration ensures that the entire current passing through the load also passes through the rheostat, allowing for effective regulation of power delivered to the load.


How you determine the load sharing of two interconnected generator?

Real power output from a generator is determined by whatever is turning the generator shaft. If one generator's prime mover is supplying ~50MW of power, and the other is supply ~50MW, they will share the load equally. If one starts generating more, it will take on more of the load. If the load doesn't change, and one starts to produce more power, the system frequency and voltage will start to increase, effectively increasing the load.


What is germane load?

Germane load refers to the cognitive load associated with the processing and understanding of information that is relevant and essential to learning a specific task or concept. It enhances learning by facilitating the integration of new information with prior knowledge, thereby promoting deeper understanding and retention. Unlike intrinsic load (related to the complexity of the material) and extraneous load (unrelated distractions), germane load is beneficial and contributes positively to the learning process. Effective instructional design aims to maximize germane load while minimizing extraneous load.

Related Questions

Explain how load sharing of generator affected?

wala gne q kabalo


What are the advantages of automatic load sharing of transformers?

advantages for automatic load sharing of transformer with protective analysis


Describe the procedure for paralleling generators explain how load sharing is affected?

Paralleling generators involves connecting multiple generators to a common bus to share the electrical load. The procedure typically includes synchronizing the generators in terms of voltage, frequency, and phase before connecting them to the bus. Once synchronized, the generators can share the load based on their capabilities, with the load distribution influenced by their respective settings, such as governor control and droop settings. Proper load sharing is crucial to ensure that no single generator is overloaded, which can be managed through coordinated control systems that adjust output based on real-time load conditions.


Power sharing is good for democracy explain with example?

Power sharing is the very spirit of democracy.Power sharing is a good way to avoid political instability and hence to maintain political order in the country.The second major reason supporting power sharing has deeper motive in the spirit of democracy. Power sharing is effective as democratic rule involves sharing power with the affected people and those who have to live with its effects, so people have a right to be consulted on how they are to be governed


Explain the Phaser diagram of inductive load?

what would be the phasor diagram of inductive load


How do you explain about cascoded amplifier?

explain about effective input noise temperature.


Can a Woodward Governor SPM-D11 be used on one generator while an Easy Gen is used on another islanded together on the same bus?

The SPM-D11 uses an independent analog signals for real and reactive load sharing. The Easygen uses a single CAN communication line for the same load sharing. As is, there is no way for them to share. However, there are Woodward devices called Load Share Gateways (LSG). There is a model for real power sharing and another for reactive power sharing. These gateways convert the Easygen CAN to SPM-D analog load sharing system. The LSG's will permit the Easygen and SPM-D to operated on a common bus.


Function of a control?

explain function below in sharing with full control?


What has the author GWR Hutchinson written?

G.W.R Hutchinson has written: 'An evaluation of load sharing strategies'


What is the most effective file sharing program?

In terms of efficient bandwidth usage and total amount shared the many implementations of bittorrent are the most effective file sharing programs. As for the most secure probably waste.


Simple file sharing is effective only when Windows XP is a member of a?

Workgroup


Explain bonding in terms of stability-a means of achieving a full outer shell either by transferring or sharing electrons?

explain bonding in terms of stability-a means of achieving a full outer shell either by transferring or sharing electrons?