This looks like the beginning of a question - but it never gets around to the question. Without a question being asked, it's pretty hard to provide an answer.
For the benefit of anyone who stumbles upon this non-question, I'm guessing that they might have been looking for the work required to supply 1 KW of heat to the reservoir of a system where the COP is 5.
COP is the acronym for "coefficient of performance". It is defined as COP = Q/W where Q is the heat supplied to or removed from the reservoir. If Q is 1kw and the COP is 5, then it would take W = Q/COP = 1 kW/5 = 0.2 kW of work to supply that heat.
Coefficiency of performance.
In case of vapour compression cycle (VCC) the COP is given by (desired effect / work input). in the other words it can be defines as what we want and what we are paying for that... so in VCC the paying amount is very less as due to low temperature difference that why its value is more than 1. but in case of vapour absorption system the COP is given by (heat taken by evaporator/ heat given to generator). the heat input taken by evaporator is less as compared to heat given to generator.. that why its COP is less than 1......
in refrigeration CoP =Qo/w= Todelta S/(Tk-To)delta S= To/Tk-ToEc = 1/(Tk/To)-1in heat pump CoP = Qk/W= Tkdelta S/(Tk-To) delta S= Tk/Tk-ToEh = 1/1-(To/Tk)
1
LTP is the power that cannot be used continuously, i.o.w. the peak current. COP means the continuous power, absorbed by -f.e.- a machine running on one level. André Hak - The Netherlands
Coefficient of performance, or COP, is defined differently for heating and cooling applications. For heating: COP=(heat supplied + work)/work For cooling: COP=(heat removed)/work Work in this case refers to the compressor and other motors.
The heat pump equation used to calculate the efficiency of a heat pump system is the Coefficient of Performance (COP) formula, which is the ratio of the heat output to the work input. It is expressed as COP Qh / W, where Qh is the heat output in watts and W is the work input in watts. A higher COP value indicates a more efficient heat pump system.
To increase the coefficient of performance (COP) of a Carnot refrigerator or heat pump, you can enhance the efficiency of the system by reducing the temperature difference between the heat source and sink, improving the insulation of the system to minimize heat losses, and utilizing more efficient components such as compressors or heat exchangers. Additionally, optimizing the working fluid and operating conditions can also help improve the overall performance of the system.
In the Heat of the Night - 1988 Good Cop Bad Cop 7-13 was released on: USA: 6 January 1994
COP in thermodynamics usually refers to the Coefficient Of Performance(sometimes CP) andis the ratio of the heating or cooling provided over the electrical energy consumed.COPheating = |QH|/W = (|QC| + W)/WCOPcooling = |QC|/WwhereQC is the heat removed from the cold reservoirQH is the heat supplied by the hot reservoirThe COP provides a measure of performance for heat pumps that is analogous to thermal efficiency for power cycles. In the case of a refrigerator, the cold reservoir is the air in the room around the refrigerator and the hot reservoir is the interior of the refrigerator - counterintuitive as that may sound. In the case of the refrigerator, the refrigerant is compressed such that it is hotter than the room, thus making it a source of heat. Part of the energy comes from the interior of the refrigerator (QC) and the rest from the work done by the compressor. When a heat pump is used to warm a building, the outside air is the hot reservoir - even though it may be colder than inside the building. Once again, the fluid used in the heat pump is compressed so that it can dump heat into the building and then when expanded outside, it is cold enough to absorb energy from the outside air.
COP of any refrigerating system mainly depends on the performance of the compressors used and the heat load at the evaporator. A similar or almost equal COP can be achieved from any system by varying its working parameters like load, kind of refrigerant used and the system working pressure. For more details contact maheshkannajpr@gmail.com
Coefficient of Performance (COP) is used for evaluating compression refrigeration systems because it reflects the cooling capacity of the system relative to the work input required to operate it. In absorption refrigeration systems, the performance is typically evaluated using the Coefficient of Performance (COP) or the Coefficient of Performance relative to the heat source (COP_Φ) since these systems use heat energy, rather than mechanical work, to operate.
The formula for the coefficient of performance (COP) of a heat pump is the ratio of the heat output to the work input. It is calculated as COP Qh / W, where Qh is the heat output in watts and W is the work input in watts. A higher COP value indicates a more efficient heat pump.
The formula for the coefficient of performance (COP) of a heat pump operating in the heating mode is the ratio of the heat output to the work input. It is calculated as COP Qh / W, where Qh is the heat output in watts and W is the work input in watts.
Coefficiency of performance.
you find out mia is an undercover cop but she helps you get away in a heat 6 cop chase
Efficiency typically refers to the ratio of useful output to input, whereas Coefficient of Performance specifically relates to the efficiency of a heat pump or refrigeration system in transferring heat from a lower temperature to a higher temperature. Efficiency is a more general term that can be applied to various systems, while Coefficient of Performance is specific to heat transfer systems.