answersLogoWhite

0

To convert 'kwh' to 'kvah' you first need to measure the length of time. You will then convert this amount to hours by dividing by 3,600. You will then divide this amount by the length of time.

User Avatar

Wiki User

11y ago

What else can I help you with?

Continue Learning about Engineering

How do you calculate kWh when load is not constant?

To calculate kWh when the load is not constant, you can integrate the power consumption over time. This involves measuring the power (in kW) at various intervals and then summing the products of power and time for each interval. The formula can be expressed as ( \text{kWh} = \int P(t) , dt ), where ( P(t) ) is the power as a function of time. Alternatively, you can use discrete measurements to approximate the integral by summing up the power multiplied by the duration of each measurement period.


How many kwh does it take to heat a water tank?

The energy required to heat a water tank depends on its size, the temperature of the incoming water, and the desired temperature increase. The formula to calculate the energy needed is: Energy (kWh) = Volume (liters) × Temperature Increase (°C) × 4.186 / 1000. For example, heating 200 liters of water from 10°C to 60°C requires approximately 42 kWh.


How can calculate ct Tod meter kWh?

To calculate the current transformer (CT) ratio for a meter measuring kilowatt-hours (kWh), you need to know the primary current (the actual current flowing in the circuit) and the secondary current (the output current from the CT). The CT ratio is given by the formula: CT Ratio = Primary Current / Secondary Current. Once you have the CT ratio, you can use it to convert the readings from the secondary side to the primary side, which is essential for accurate energy measurement in kWh. Finally, ensure that the meter is calibrated according to the CT ratio for accurate readings.


How much does 1 MW equals in terms of KWH of electricity?

1000


How many watts are in a kwh?

A 1000 watt device operated continusouly for 1 hour would equal 1 Kwh.

Related Questions

When power factor is unity then what would be equal?

Kwh will equal to Kvah.


Working principle of trivector meter?

trivector meters are used to measure kVAh and also kVA of maximum demand.it has a kwh meter and reactive kvah meter in a case with special summator mounted between them.


Maximun demand tariff I have a company which works 24 7 with has an average load which is constant at 100kw at 7 lagging power factor i want to know the annual energy cost of running the company?

On a KWh billing systemOn a kVAh billing systemtariff 1 euro 20.50/KW Each kWh@14c7tariff 2 euro 19.20/KVA Each kVAh@13c5


How do you work out total cost of 35kwh to cost per kwh?

To calculate the cost per kWh given 35 kWh of usage and the total cost, divide the total cost by the number of kWh. For example, if the total cost is $70 for 35 kWh, the cost per kWh would be $70 / 35 kWh = $2 per kWh.


What is the meaning of kvah?

A kV.A.h (not 'kvah') is a kilovolt ampere hour. You can think of it as being the vector sum of 'active' (kW.h) and 'reactive' (kvar.h) energies.


What is meaning of kvah?

A kV.A.h (not 'kvah') is a kilovolt ampere hour. You can think of it as being the vector sum of 'active' (kW.h) and 'reactive' (kvar.h) energies.


How you calculate import Kvarh in percentage?

P.F = Kwh/Kvarh


How do you calculate 3 phase motor kWH where voltage are 440 and amps are 11?

To calculate the kWh consumed by a 3-phase motor, you'll need to know both the power factor and operating hours. The formula is: kWh = (√3 x Volts x Amps x Power Factor x Hours) / 1,000. Without the power factor and hours of operation, a precise kWh calculation cannot be provided using just voltage and current.


What is the cost of operating a 3.00 W electric clock for a year if the cost of electricity is .09 kWh?

To calculate the cost of operating the electric clock for a year, first convert the power rating to kWh: 3.00 W = 0.003 kW. Then calculate the total energy consumed in a year: 0.003 kW * 24 hours/day * 365 days = 26.28 kWh. Finally, multiply the total energy consumed by the cost per kWh: 26.28 kWh * $0.09/kWh = $2.36 for operating the electric clock for a year.


How much does it cost to use a 9 kwh shower for half an hour?

To calculate the cost, you need to know the cost per kilowatt-hour (kWh) from your utility provider. Multiply the kWh of the shower unit (9 kWh) by the duration (0.5 hours) to get the total energy used. Then multiply this by the cost per kWh to get the total cost.


How much money does 1600 kWh cost?

The cost of 1600 kWh depends on the electricity rate charged by your utility provider, which can vary by region and provider. For example, if the average rate is $0.13 per kWh, then 1600 kWh would cost approximately $208. To calculate the exact cost, multiply the total kWh by your specific rate.


How is CO2 output calculated from kWh?

To calculate CO2 output from kWh, you would need to know the carbon intensity of the electricity source. This is typically measured in pounds or kilograms of CO2 per kWh. You can multiply the carbon intensity by the number of kWh consumed to estimate the CO2 emissions produced.