You can't have a three phase earth fault, you can have a phase to phase or a phase to earth fault. If you want the potential phase to earth fault current it will be your voltage times your impedance. If you want the phase to phase potential fault current then you should just double the above result.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Engineering

How do you calculate internal fault loop impedance?

by calculating the loop current


What is earth fault loop impedance?

An earth-fault loop is the path taken by the fault current, when an earth-fault occurs within an electrical installation, and comprises a series circuit made up ofthe utility company tranformer's low-voltage winding,the utility company's distribution cable's line conductor,the consumer's line conductor to the point of an earth fault,the consumer's earthing conductor,and the resistance of the earth path back to the transformer.The combined opposition of this series circuit to the flow of fault current is termed the earth-fault loop impedance, expressed in ohms.


What is varley loop test?

A varley loop test is a test used to find the earth fault location in an underground cable. It uses the Wheatstone bridge to help determine the distance from the test point to a fault in a telephone or telegraph line or cable.


Where the phased locked loop is used?

Phase lock loop is used in analog and digital communications to keep the phase of the output signal the same as the input signal.


How do you do a earth loop impedance calculation?

The earth-fault loop includes the consumer's line conductor, the consumer's protective conductor, and the earth parth external to the consumer's installation (including the low-voltage winding of the transformer, the distribution line conductors to the installation, and the earth return path.The purpose of this test is to measure the actual value of the earth-fault loop impedance and to confirm that its value complies with the tabulated maximum values listed in BS 7671:2008 Regulations for Electrical Installations, Tables 41.2 - 41.5. The value must be low enough to enable sufficient fault current to flow to cause any overcurrent protection device to operate within the periods specified -i.e. 0.4 s for circuits supplying socket outlets and fixed equipment in bathrooms, and 5.0 s for circuits supplying fixed equipment.The theory behind the test is as follows. With no current flowing around the loop, there are no voltage drops and, so, the transformer's full open-circuit voltage (U1) will appear between the line and protective conductors at the point where the test is conducted.A simulated earth fault is then applied, by inserting a current-limiting resistor between the line and protective conductors. The resulting fault current (IF) is then measured, together with the voltage drop (U2) across the limiting resistor. The duration of this fault should not be allowed to exceed two cycles (40 ms at 50 Hz) to avoid damaging the circuit.The earth-fault loop impedance is then calculated by dividing the difference between the two voltages (U2 - U1) by the resulting fault current (IF), which will give the impedance of the complete loop (including the limiting resistor), from which we must then subtract the value of the limiting resistor.As the simulated earth fault must not exceed 2 cycles, this (theoretical) test obviously cannot be conducted with a voltmeter and an ammeter, and so it is conducted with a commercial instrument, called an earth-fault loop tester, which performs all the measurements (U1, U2, IF), makes all necessary calculations, and provides an digital readout directly in ohms -while, at the same time limiting the duration of the test to less than 40 ms.Before conducting the test, the continuity of the protective conductors must have been confirmed. If the test was to be performed with a break in the protective conductor, then the protective conductor up to the point of that break would represent a safety hazard to anyone in contact with equipment at the time.

Related Questions

How do you calculate internal fault loop impedance?

by calculating the loop current


What is earth fault loop impedance?

An earth-fault loop is the path taken by the fault current, when an earth-fault occurs within an electrical installation, and comprises a series circuit made up ofthe utility company tranformer's low-voltage winding,the utility company's distribution cable's line conductor,the consumer's line conductor to the point of an earth fault,the consumer's earthing conductor,and the resistance of the earth path back to the transformer.The combined opposition of this series circuit to the flow of fault current is termed the earth-fault loop impedance, expressed in ohms.


What is varley loop test?

A varley loop test is a test used to find the earth fault location in an underground cable. It uses the Wheatstone bridge to help determine the distance from the test point to a fault in a telephone or telegraph line or cable.


Where the phased locked loop is used?

Phase lock loop is used in analog and digital communications to keep the phase of the output signal the same as the input signal.


Open loop fault during idle on a hyundai.what does that mean?

Means the PCM has detected a fault with the closed loop system, and is operating in open loop fault. Open loop is a program that the PCM runs during start up, and continues to run until the PCM decides the o2 sensor is hot enough to be relied on for fuel control. closed loop runs relies on the o2 sensor for fuel control. open loop fault happens when an error is reported. look for O2 sensor DTCs.


If a 240V circuit is protected by a 15A simi-enclosed fused and has an electrical earth-fault loop impedance of 1.9 ohms determine the earth fault current in the event of a zero impedance earth fault?

I am assuming that its a 240 Volt AC circuit supplying an inductive load with a fault loop impedance of 1.9 ohms at the time of the short circuit. The power factor is assumed to be 0.8 The instantaneous earth fault current value would be; Current = (Voltage x Power Factor) / Impedance (240 x 0.8) / 1.9 192 / 1.9 = 101 Amps. However this may be a trick question as it doesn't ask for an instantaneous value, the fuse will limit the fault current to 15 amps and should disconnect the circuit within 0.4 seconds.


What is ic 565?

The LM565 is a phase locked loop.


How do you calculate loop length?

the multiplication of the number of iterations with the number of statements in that loop is equal to loop length.


How do you do a earth loop impedance calculation?

The earth-fault loop includes the consumer's line conductor, the consumer's protective conductor, and the earth parth external to the consumer's installation (including the low-voltage winding of the transformer, the distribution line conductors to the installation, and the earth return path.The purpose of this test is to measure the actual value of the earth-fault loop impedance and to confirm that its value complies with the tabulated maximum values listed in BS 7671:2008 Regulations for Electrical Installations, Tables 41.2 - 41.5. The value must be low enough to enable sufficient fault current to flow to cause any overcurrent protection device to operate within the periods specified -i.e. 0.4 s for circuits supplying socket outlets and fixed equipment in bathrooms, and 5.0 s for circuits supplying fixed equipment.The theory behind the test is as follows. With no current flowing around the loop, there are no voltage drops and, so, the transformer's full open-circuit voltage (U1) will appear between the line and protective conductors at the point where the test is conducted.A simulated earth fault is then applied, by inserting a current-limiting resistor between the line and protective conductors. The resulting fault current (IF) is then measured, together with the voltage drop (U2) across the limiting resistor. The duration of this fault should not be allowed to exceed two cycles (40 ms at 50 Hz) to avoid damaging the circuit.The earth-fault loop impedance is then calculated by dividing the difference between the two voltages (U2 - U1) by the resulting fault current (IF), which will give the impedance of the complete loop (including the limiting resistor), from which we must then subtract the value of the limiting resistor.As the simulated earth fault must not exceed 2 cycles, this (theoretical) test obviously cannot be conducted with a voltmeter and an ammeter, and so it is conducted with a commercial instrument, called an earth-fault loop tester, which performs all the measurements (U1, U2, IF), makes all necessary calculations, and provides an digital readout directly in ohms -while, at the same time limiting the duration of the test to less than 40 ms.Before conducting the test, the continuity of the protective conductors must have been confirmed. If the test was to be performed with a break in the protective conductor, then the protective conductor up to the point of that break would represent a safety hazard to anyone in contact with equipment at the time.


When will a negative feedback amplifier circuit be unstable?

It will oscillate if the loop gain exceeds 1 when the phase difference round the loop is 360 degrees. The frequency of oscillation is set by the loop phase being equal to 360 degrees.


What is an ADPLL?

An ADPLL is an all-digital phase locked loop - a control system that generates an output signal whose phase is related to the phase of an input signal.


What makes closed-loop op amp unstable?

A: It does not. The loop becomes unstable ONLY if there is positive feedback either voltage or phase. For a close loop to be stable negative feedback is required.