Circuit breakers are used to protect the conductor that is connected to it. The sizing of the conductor is based on the current of the load. As the connected load current is increased so must the wire size to accommodate that higher current. Therefore as the wire size increases so must the breaker size to accommodate the higher load current.
32A MCB to be used
TPN MCB means Triple pole Neutral Miniature Circuit Breaker where as SPN MCB means single phase Neutral MCB.
While selecting an MCB you have to check: 1) Current Rating; 2) Response Time; 3) Manufacturer; 4) Type of MCB (means single pole, double pole, three pole, four pole - it depends on the application); 5) Cost; 6) short circuit breaking capacity. For more information see the answers to the Related Questions and the Related Link shown below.
Divide the output rating by the input rating
c curve & d curve mcb difference
32A MCB to be used
An immersion heater typically requires a dedicated circuit with a Miniature Circuit Breaker (MCB) rated at 16A or 20A, depending on the power rating of the heater. It is recommended to consult with a qualified electrician to determine the appropriate MCB rating based on the specific requirements of the immersion heater.
To calculate the range of an MCB (Miniature Circuit Breaker) for a motor circuit, you need to consider the full load current of the motor in amps and select an MCB with a rating above this value to ensure it can handle the starting current and any potential overload conditions without tripping. It is recommended to select an MCB that is rated at least 1.5 times the full load current of the motor to provide a safety margin and prevent nuisance tripping.
It its rating is 63 amps that means the current can be anything from 0 to 63 amps but not more.
TPN is same as 4P MCB TPN means Three Pole and Neutral - four pole MCB. 4P is four pole MCB
.
TPN MCB means Triple pole Neutral Miniature Circuit Breaker where as SPN MCB means single phase Neutral MCB.
While selecting an MCB you have to check: 1) Current Rating; 2) Response Time; 3) Manufacturer; 4) Type of MCB (means single pole, double pole, three pole, four pole - it depends on the application); 5) Cost; 6) short circuit breaking capacity. For more information see the answers to the Related Questions and the Related Link shown below.