It is not necessary to design an 11 kv underground cable. There are several 11 kv underground cables already on the market. You can choose exactly which cable will fit best for your project and purchase it.
If you are referring to an 11-kV underground cable, these are normally armoured and, in the case of older cables, have a lead sheath to prevent moisture ingress into the cable. The lead sheath and metal armour are earthed to ensure that, in the event of mechanical damage to the cable, there is a low-resistance path back to the source to sufficient earth-fault current flows in order to operate the circuit's protective system. Overhead lines do not normally have a separate earth conductor.
It depends on the design of the transformer but 1 MVA is a common size for an 11 kV / 415 v three-phase transformer.
4444
if we take 11kv /33kv yhe current produced will be less when compared to 230v/11kv.. the curent produced will be gerater than 1000amp or above so the winding of the transformers will damage because thier is no winding at present to with stand the huge amount of current by K.B.N.GANGADHAR sasi institute of technology and engineering
750MVA to 1000MVA for 33kV and 350MVA for 11kV
It is a cable that feeds.
If you are referring to an 11-kV underground cable, these are normally armoured and, in the case of older cables, have a lead sheath to prevent moisture ingress into the cable. The lead sheath and metal armour are earthed to ensure that, in the event of mechanical damage to the cable, there is a low-resistance path back to the source to sufficient earth-fault current flows in order to operate the circuit's protective system. Overhead lines do not normally have a separate earth conductor.
Armoured cable is not rated for underground installations. You have to use a cable with a designation for direct burial or wet and damp locations.
The best cable burying tool for burying cables underground efficiently and effectively is a cable trencher.
300mm
It depends on the design of the transformer but 1 MVA is a common size for an 11 kV / 415 v three-phase transformer.
URD cable, or Underground Residential Distribution cable, is a type of electrical cable designed for use in underground power distribution systems. It is commonly used to deliver electricity from utility poles to residential and commercial buildings. URD cable is insulated to protect against moisture and other environmental factors, making it suitable for burial underground.
These are different types of electrical cables used for various applications. Service entrance cable is used to connect the utility power to a building's main electrical panel. Underground feeder branch circuit cable is used for underground wiring between buildings or from the main panel to subpanels. Mineral insulated cable is a type of fire-resistant cable used in high-temperature environments. Jacketed cable refers to any cable with an outer protective covering for mechanical and environmental protection.
600mm is the distance between two conductors in 11kv line
Cable companies utilize satellite technology to initially get the signal, then it is distributed via underground or above ground cable.
A digital voltmeter with a range up to 11kV would be suitable for measuring a voltage of 11kV. Ensure the voltmeter is rated for the high voltage to be measured and follow safety protocols when working with high voltage systems.
Time Domain Reflectometers can be used to locate where an underground cable fault lies. Time Domain Reflectometry (See wikipedia) is a measurement technique to identify the location using reflected signals sent down the cable line.