Open a vent valve to purge the air and open the supply valve to let in water.

Every hydronic (forced hot water) system has a system fill or supply valve, often connected to domestic cold water through a flow-check valve and a pressure-reducing valve. However, simply opening this valve with the rest of the system closed will merely pressurize the system with air. The system should also have one or more automatic air vents, plus a purging valve or two. By allowing air to vent (often out the top) and air bubbles to pour out through the purge valves, you can mostly fill the hydronic system with water. As the system is then heated, more air bubbles will form from dissolved air and be vented by the automatic vents. If it is not automatically vented, the top-most loop of the system may accumulate air and stop working until it is purged by opening a vent until water comes out.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Engineering

How do you calculate the amount of water in a central heating system ..pipe and radiators?

One would need to know the pipe sizes, boiler and expansion tank capacity and total length of pipe etc to figure the system`s volume. So instead, drain it, look at the water meter reading, fill it, look at the meter again and subtract the first reading from the second.


Hot water baseboard heating system?

Hot water heating systems must be free of air to operate properly. The art of purging air from one of these systems comes with experience. There are usually purge setups in the piping, if the system was installed properly. The purge setup will consist of one ball valve or gate valve and one boiler drain somewhere in the loop or zone. There should be a half inch copper line connected to the water in the house that's used to fill the boiler and to purge air. This line will have an auto feeder valve somewhere between the tie into the water lines and the boiler. There is a lever on top of the auto feed valve. This lever is to override the automatic setting that keeps the boiler at the right pressure. When lifted up the lever allows city water pressure to be fed into the boiler. When the lever is down the setting will be somewhere between 12 and 25 pounds. This safeguards the system in case of a leak somewhere. Water will be added automatically. The way we purge the system is by hooking a hose to the boiler drain in the purge setup. Close the ball or gate valve and feed water through the system and out the boiler drain. The ball valve is to make sure the water we're putting in goes through the entire system before exiting. After the hose is hooked up and opened and the ball valve is closed, lift the lever on the automatic feeder and force city water into the boiler, around the loop your purging and out the hose. Be sure to watch the pressure gauge on the boiler and never exceed twenty five pounds. You will set off the pressure relief valve at 30 pounds. This is why the hose must be opened before the lever is lifted on the auto feeder. Put the hose end into a five gallon bucket and watch for air bubbles. Once the air bubbles have subsided, allow the system to purge for a few more minutes. Close the lever on the auto feeder and then the boiler drain. Open the ball valve and you're done.


How do I add water to my home radiator system while bleeding the air out?

At you boiler, near your expansion tank, is a pressure reducing valve that puts water into the system automatically. The PRV should be set to maintain a pressure 4 psig more than the height of the system. i.e. PSIguage = (height of system x .43 PSIg / ft) + 4 psig i.e = ( 24 ' from fill point to top of system * .43 psi / ft) + 4 = 10.3 + 4 = 14.4 psig (set point of automatic makeup water valve) FYI: PRV valves normally come set at 12 psig out of the box. The fact you need to bleed air would lead me to believe that either your PRV set point is not high enough to keep air out the system, or your pump is located upstream of you makeup water point (pumping to the makeup water point) rather than pumping away from it.


How do you fill a toilet drain not in use?

You can't fill a toilet drain not in use as there is no 'trap' to fill with water. The best thing is to get a toilet flange cover from a plumbing store and install it on the toilet flange - i.e. the circular fitting in the floor that the toilet would normally sit on.By simple pouring a few gallons of cold water to replenish the trap seal of the fixture .. check it every few weeks to make sure there is still water above the crown weir


How do you safely weld a gas tank?

I have fixed a couple over time and what I do is fill it with water and detergent empty it out Then do it again, then Weld it.

Related Questions

How do you safely fill and purge a hydronic -- hot water baseboard -- heating system?

previous answer is typical. Hire a PLUMBER!!


How can I install a hot water floor heating system in my home?

To install a hot water floor heating system in your home, you will need to first determine the type of system that best suits your needs, such as hydronic or electric. Next, you will need to plan the layout of the system, including the location of the tubing or heating elements under the floor. Then, you will need to install the tubing or heating elements, connect them to a boiler or water heater, and fill the system with water. Finally, you will need to test the system to ensure it is working properly and make any necessary adjustments. It is recommended to consult with a professional for guidance and assistance during the installation process.


How do you know the bladder in a hot water heating system is good?

If the bladder is bad in your expansion tank the tank will fill with water. When this happens the pressure in your furnace will exceed 30lbs and your pressure relief valve will blow off.


After replacing a hot water heater what should you do?

You should check and adjust the heating temperature, then turn on the cold water to fill the tank.


How do I add antifreeze to hot water heat system?

My heating system currently has antifreeze in it. The system is completely isolated from the house water system. A small RV water pump is used to fill the system and pressurize properly. I do not know the type of antifreeze used in the system. With complete isolation, automotive should be acceptable. I am investigating RV antifreeze as well. Automotive antifreeze is toxic. There must be no connection between the heating system and the potable water systems. Isolation valves are not acceptable.The usual FHW heating in a home or other building is connected to the water (drinking water) supply with a pressure valve at the boiler.Automotive antifreeze is deadly and can cause blindness even in small amounts.There is a special antifreeze (non toxic) for use in heating systems where a backup/mix/crossover with the drinking water could occur.You could also burn out your circulation pump by using the wrong antifreeze, which is very expensive to replace.


How does air get into central heating or radiators?

Air ends up in hydronic (hot water heating) systems in the following ways:1. The system has just been installed or repaired, and it has been filled with fresh, air-laden water. Heating the water will purge the air, which then typically collects in high points. It will need to be purged out of the system.2. A leak in the system causes fresh water to refill the system (through the feedwater valve).3. Air migrates from the expansion tank (where it belongs) to one or more radiators (where it doesn't).We don't want air in the system because:a. the oxygen in it causes corrosion; andb. it blocks the flow of heating water.The way to repair the above problems is:for 1. -- to purge the air from bleed valves daily until no air remains.for 2. -- to locate and repair the leak, and then fill and purge.for 3. --to purge the system, and also empty the expansion tank of water.The HVAC Veteran


How did mandingo die?

He was forced to fill up a large vat with water, build a fire under it and then immerse himself in it. He was boiled alive


How does radiant heating work?

Radiant heating works by transferring heat directly from a warm surface to objects and people in a room. This can be done through electric resistance heating, hydronic heating (using hot water circulated in pipes), or radiant panels. The heat radiates outwards, warming up the surrounding area without the need for forced air or ductwork.


What is the purpose of the fill valve seal in a plumbing system and how does it contribute to the proper functioning of the system?

The purpose of the fill valve seal in a plumbing system is to prevent water from leaking out of the tank. It contributes to the proper functioning of the system by maintaining the water level in the tank, allowing for efficient flushing and refilling of the toilet.


How do you calculate the amount of water in a central heating system ..pipe and radiators?

One would need to know the pipe sizes, boiler and expansion tank capacity and total length of pipe etc to figure the system`s volume. So instead, drain it, look at the water meter reading, fill it, look at the meter again and subtract the first reading from the second.


How is heat is lost through windows?

Heat from your house is used heating the window, which then is used heating up outside, which is actually just cooled by outside. Think of it like trying to fill up cups with water: ( Ignore the ````'s) ````````````________ ````````````( ~_~__~_ ````````````(_) Tap(Heating) `````````````~ `````````````~ ````````` / ````~ ~ ~ \~| ``~ \ ~ ~ / | | \ ~ / | ~ ~| |_~_| | ~ | |_~_| House | ~ | Window ` Outside


What would cause a tub to fill with water in your upstairs condo?

Water can come from the tap or it can come from the drain -- one or the other.Assuming that you didn't turn on the water to fill the tub, perhaps the sewer system drains are backed up.