Motor terminals typically feature two types of connections—star (Y) and delta (Δ)—to accommodate different voltage and current requirements during operation. The star connection allows for lower voltage and higher current, making it suitable for starting the motor, while the delta connection enables higher voltage and lower current for efficient running at full load. This dual connection system enhances flexibility, allowing the motor to perform optimally under varying conditions.
two contecter <<>> There are three contactors used in a Star Delta configuration.
i think its use for 3 phase connection.
I Rather not think that you can buy 2 farad capacitor and no the terminals must follow polarity guidelines.
In 3phase induction motor, stator winding splited into 3windings (Each winding conductor size, no of turns etc are equal to each other). So 3 windings have 6terminal. Generally all 6 terminals are taken out for termination on 5HP and above rated 3phase motors. So, that motor can be started with star / delta starters to reduce starting current (DOL starter does not reduce starting current). Major advantage is It is easy to change the connection (STAR / DELTA) acoording to the purpose going to be used. Also starting and ending terminal to be marked properly.
A: In the USA there is D delta connection or Y connection. The Y center point may not be zero if there is circulating current due to mismatch of the phases
Motor terminals typically feature two types of connections—star (Y) and delta (Δ)—to accommodate different voltage and current requirements during operation. The star connection allows for lower voltage and higher current, making it suitable for starting the motor, while the delta connection enables higher voltage and lower current for efficient running at full load. This dual connection system enhances flexibility, allowing the motor to perform optimally under varying conditions.
Star Star TransformerStar Star Transformer is formed in a 3 phase transformer by connecting one terminal of each phase of individual side, together. The common terminal is indicated by suffix 1 in the figure below. If terminal with suffix 1 in both primary and secondary are used as common terminal, voltages of primary and secondary are in same phase. That is why this connection is called zero degree connection or 0o - connection.If the terminals with suffix 1 is connected together in HV side as common point and the terminals with suffix 2 in LV side are connected together as common point, the voltages in primary and secondary will be in opposite phase. Hence, Star Star Transformer connection is called 180o - Connection, of three phase transformer.Vikram Meena
Dirty connection
The definition of star connection is a connection of the ends of phase windings at the star point.
hahahaa
The potential difference between the terminals of a connection wire is determined by the voltage difference applied across the wire. This voltage difference creates an electric field within the wire that causes charge carriers to move and establish a potential difference between the terminals.
two contecter <<>> There are three contactors used in a Star Delta configuration.
i think its use for 3 phase connection.
I Rather not think that you can buy 2 farad capacitor and no the terminals must follow polarity guidelines.