Why can the neutral wire diameter be reduced in relationship to the phase wires?

The Neutral wire should be the same gauge and size of the phase wires. Only the Earth or Equipment wire can be smaller than the phase(hot) wires. <<>> On a three phase four wire distribution system the neutral can be reduced in size. The neutral only carries the unbalanced load current and should be sized to that current. The highest current load to neutral of the three legs is used to calculate the neutral sizing. There is no reduced neutral allowed on discharge lighting and non linear loads. A demand factor of 70% shall be permitted to be applied to that portion of the unbalanced load in excess of 200 A.


Can you tap off a 3 phase 277volt ac light fixture to power a single phase 120 volt ac recptacle?

NO! The voltages available in the 3-phase system are 480 (if you wire phase to phase) and 277 (if you wire phase to neutral) Don't try it!


What is the minimum volt rating of wire used in a 3 phase 4160 volt phase to phase system?

5000 volt


What are the procedures for the connection of single and 3 phase circuits?

Single phase connection has 1 phase wire and a neutral wire. Another wire for protective earth. In three phase system, motor can be connected in star or delta. Most AC induction motors are in Delta. Power distribution system is generally 3 phase 4 wire. Transmission system is 3 phase high voltage. Industry uses 3 phase system, where as 1 phase is for domestic, commercial applications. Both 1 and 3 phase system has a frequency. It is either 50 Hz or 60 Hz, depending upon the country or region.


Can a bad circuit breaker on a 3 phase motor cause the motor to run backwards?

No. If the motor runs backwards, swap any two phases to reverse the rotation, like this: Old wiring: phase A - brown wire - motor lead T1 phase B - yellow wire - motor lead T2 phase C - orange wire - motor lead T3 New wiring: phase A - brown wire - motor lead T2 phase B - yellow wire - motor lead T1 phase C - orange wire - motor lead T3

Related Questions

How do you bypass code on a phase linear uv7i?

ground pink wire


Phase linear UV7i sound cuts off when over 20 volume Why?

check the ground wire and ground it ti the car


How do you reset phase linear uv7i?

Press the RESET button located in the bottom right corner of the front panel


How do you bypass the emergency brake on your phase linear UV7i installation to watch movies while driving?

Well you can run the pink wire to the fuse box then add a switch.....When prompt to do so turn switch on for five seconds......Then turn it back off.....Then turn back on and leave on....TV will come on in 1-2 seconds.


When was Phase Linear created?

Phase Linear was created in 1972.


Phase linear uv8 bypass code for parking brake without a remote?

phase linear uv8020 bypass code for parking brake without remote?


How do you reverse a direction of a slip ring motor?

It is very simple. Just interchange any two phase wires. i.e. Y and B ( or ) R and B ( or ) R and Y for example Stop the supply. keep R phase wire as it is and disconnect B phase wire and Y phase wire. Connect B phase wire to the Y phase motor stud and Y phase wire to the B phase motor stud. Now give the supply, now motor revolves in opposite direction to the earlier.


Explain the comparison between dc 2 wire system and ac single phase 2 wire system and ac 3 phase 3 wire system and ac 3 phase 4 wire system?

of all of dem 3 phase 3 wire is most economical as it uses less conductor dan in 4 wire system, 3 phase 3 wire is used in transmission and 4 wire in distribution as it has 3 live and one neutral wire. 3 phase needs lesser conductor size than 2 phase 4 wire for the same power. 3 wire dc feeder is more economical than 2 wire dc feeder for the same power. that was all i cud get..... hope u find it a lil helpful.


Why can the neutral wire diameter be reduced in relationship to the phase wires?

The Neutral wire should be the same gauge and size of the phase wires. Only the Earth or Equipment wire can be smaller than the phase(hot) wires. <<>> On a three phase four wire distribution system the neutral can be reduced in size. The neutral only carries the unbalanced load current and should be sized to that current. The highest current load to neutral of the three legs is used to calculate the neutral sizing. There is no reduced neutral allowed on discharge lighting and non linear loads. A demand factor of 70% shall be permitted to be applied to that portion of the unbalanced load in excess of 200 A.


Can you tap off a 3 phase 277volt ac light fixture to power a single phase 120 volt ac recptacle?

NO! The voltages available in the 3-phase system are 480 (if you wire phase to phase) and 277 (if you wire phase to neutral) Don't try it!


Which connection is best suit for 3 phase 4 wire service and why?

STAR connection is best suit for 3 phase 4 wire seviceas there is a neautral wire is there in this connection


What is linear density of wire?

Linear density of a wire refers to the mass per unit length of the wire, typically expressed in units such as grams per meter or kilograms per kilometer. It is calculated by dividing the mass of the wire by its length. Linear density is an important parameter in engineering and materials science, as it can affect the wire's mechanical properties and performance.