Yes, many parts of the US use 13.2 kV in primary line distribution systems. That is phase to phase. Phase to ground is 7620 V.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Engineering

What is Indian railway transmission line voltage?

220v, 415v, 6.6 kv, 11kv,33kv,132kv,400kv


What is 11 kV single phase?

for USA, Canada and other countries running a 60 Hz supply service.A 11kV single phase line is one phase of a three phase system. The three phase system voltage is found by multiplying 11kV x 1.73. The three phase primary system voltage is 19kV. A transformer with a 11 kV primary can have a secondary of 115/230 depending on the internal connections in the transformer's case.For the UK11 kV is the standard three-phase h.v. distribution voltage in the UK, where it is a line voltage (i.e. it is the voltage measured between any pair of the three line conductors). A single-phase distribution transformer is connected between any two lines, so 'single-phase 11-kV' is simply a connection made between any two lines of an 11-kV three-phase system.As the primary windings of three-phase 11-kV distribution transformers are delta (3-wire) connected, the primary phase voltage is numerically equal to the primary line voltage (11 kV).


What is the line current in HT line of 11 KV?

it is depends on the rating of distribution transformer,e.g if there is 100 kva, then it will take 5.25amp.


Does line to ground voltage always half the value of line to line voltage?

Line to Ground voltage = line to line voltage / 1.73AnswerIt depends what configuration is being measured. In the case of the secondary of a split-phase distribution transformer used to supply residences in North America, the answer is yes. In the case of a star (wye) connected secondary distribution transformer used to supply residences in Europe, no: the line to ground voltage will be as described in the first answer.


Is a Potential Transformer a step down transformer?

PT's are typically used for metering and relaying purposes to sample the power system voltage and phase angles. The primary is at line voltage, and the secondary is typically between 66 - 120 volts (depending on primary connection, Line to Line or Line to Neutral). So yes, PT's are step down transformers.

Related Questions

What is the maximum run of primary cables when secondary distribution center are grouped at the end of an electrical distribution line?

1 mile


Name an electrical application that requires insulators?

Primary line power distribution system.


Safety distance from 132kv power line?

The safety distance from a 132 kv powerline is 1.4 metres


Why there is no neutral conductor in power transmission lines?

Using a distribution system (e.g. 11 kV in the UK) as an example, the primary of a three-phase distribution transformer is delta-connected, which requires to be supplied by three line conductors. So a neutral conductor is superfluous.


What is Indian railway transmission line voltage?

220v, 415v, 6.6 kv, 11kv,33kv,132kv,400kv


What do you use to connect the energizing line side to the output feeder side of the primary distribution center?

arc-strangler switchblades


Explain the transmission and distribution of electricity from the generation station to the consumer?

transmission and distribution of electricity are the way of regulate voltage to the minimum rate in which can be benefit to the consumers. From generating station , voltage generated is up 16/25kv which step up upto 330kv this generating voltage now step down in the transmission station through the step down transformer which is 132kv this voltage now transmitting to distribution station where voltage now step down to 33kv, this 33kv now stepdown to 415v for three line and 240/220v for a line for the uses of consumers.


Is current ratio of transformer constant on loads?

the current ratio I1/I2 is a constant for all loads. the total current drawn on the secondary winding of a transformer depends on the total circuit impedance as seen by the transformer output terminals. considering that the power in primary is equal to the power in the secondary and is a constant (assuming no losses as per the principle of conservation of energy). The input voltage(primary) is a constant i.e equal to the primary distribution line voltage, and the secondary distribution line voltage is also operated at a constant value. therefore KVA(primary) = KVA( secondary) V1I1=V2I2 I1/I2 =V2/V1 which is a constant irrespective of the load.


What line deliver electricity to your home?

Distribution lines


What is a line that lies far from the center of a distribution?

it is nothing


Why generally the high voltage side of transformer is delta connected?

I don't know what kind of transformer you are talking about, but most utility distribution transformers are star connected on the primary side.AnswerIt might be different in some other countries, but in the UK, three-phase distribution transformers are always connected in delta on their primary (high voltage) side, and in star (wye) on the secondary (low voltage) side. The primary line voltage is 11 kV, while the secondary line/phase voltages are 400 V and 230 V.In the United States and Canada, the primary winding is also connected in delta -however, the secondary side is also connected in delta, with one phase centre- tapped to provide the split-phase 240/120 V arrangement.The reason for using a delta connection is because three-phase high-voltage lines are supplied as three line conductors -there is no provision for a neutral- so there is no practical advantage in having a star-connected primary.