answersLogoWhite

0

It can be in either location, depending on your head pressure ie a circ on the head or "pump away" will circulate water better in upper floors. If the system is in a 2 or 3 story house using standard baseboard, then having the circulator in either position wont matter. Most all manufacturers are shipping and or directing installers to pump away...circulator on the supply....

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Engineering

How does water mix in under floor heating systems?

A thermally controlled mixing valve is connected between the hot supply line and the return line, tempering the hot supply with the cooler return water.


How does a forced-air heating system work?

Room air is drawn into the return air ducts and proceeds to a squirlcage or "sirocco" fan. The air is then discharged into the furnace's heat exchanger where the hot flue gases from the fire are cooled by the air and the air is warmed. This warm air is then forced through the heating supply ducts and up through the warm air registers in each room. Forced air systems can also include a humidifier, to add moisture to the air, filters to clean the air. and special filters to remove odors or ultra-violet lamps to sanitize the air.


Where should a service valve be located in order to isolate the hot supply from the hot water storage vessel to the taps?

primary flow


What is the default return type in C and C plus plus?

No. There is no default return type for functions, it must be explicitly specified in both the function declaration and in the definition. To specify no return value, return void. To return a variant type, return void* (pointer to void). Otherwise return the exact type.


What ways can object oriented systems be considered cure to the software crisis?

It isn't clear what you mean by the "software crisis". The benefits of object oriented systems are usually in the re-use of code (not having to write the same type of code over and over again), which leads to a better ROI (return on investment). This means you can leverage what you already have done to get a product to market faster.

Related Questions

Do you need a cold air return on your furnace?

YES! If you do not have a cold air return on your furnace, you will have much higher heating bills as you will not be circulating the cold air from your home back to the furmace to be heated again.


Where are the return air vents located in a typical HVAC system?

Return air vents in a typical HVAC system are usually located on the walls or ceilings of a room, allowing air to flow back into the system for heating or cooling.


How does water mix in under floor heating systems?

A thermally controlled mixing valve is connected between the hot supply line and the return line, tempering the hot supply with the cooler return water.


In addition to an inadequacy of circulating volume venous return and cardiac output are?

decreased


Where is the Rheem furnace filter located in the heating system?

The Rheem furnace filter is typically located near the air handler or blower unit in the heating system. It is usually found in the return air duct or inside the furnace cabinet. Regularly changing or cleaning the filter is important for maintaining the efficiency and performance of the heating system.


Should cold air return be running constantly?

You will hear air circulating in the cold air return (or return air grille) when the heater or air conditioner is running.


What does a return vent look like and where is it typically located in a home?

A return vent is usually a large grate on a wall or ceiling that allows air to flow back into the heating or cooling system. It is typically located in a central area of a home, such as a hallway or living room, to efficiently circulate air throughout the house.


What are the key differences between HVAC return and supply systems, and how do they impact the overall efficiency and performance of a heating, ventilation, and air conditioning (HVAC) system?

The key difference between HVAC return and supply systems is that the return system brings air back to the HVAC unit to be heated or cooled, while the supply system distributes the conditioned air throughout the building. The efficiency and performance of an HVAC system are impacted by the balance between the return and supply systems. If the return system is not functioning properly, it can cause the HVAC unit to work harder to maintain the desired temperature, leading to higher energy consumption and reduced efficiency. Similarly, if the supply system is not distributing air effectively, it can result in uneven heating or cooling throughout the building, leading to discomfort for occupants and potential strain on the HVAC unit. Therefore, ensuring that both the return and supply systems are properly designed, installed, and maintained is crucial for optimizing the efficiency and performance of an HVAC system.


What is the purpose of a basement cold air return in a heating and cooling system?

The purpose of a basement cold air return in a heating and cooling system is to circulate and return cold air from the basement back to the furnace or air conditioner for re-heating or re-cooling. This helps maintain a balanced temperature throughout the home and improves the overall efficiency of the system.


What material can return to their original shape after heating?

Shape memory alloys, such as Nitinol, can return to their original shape after being deformed when heated. These materials exhibit unique characteristics that allow them to "remember" their original shape and revert back to it upon heating.


Is it recommended to install a floor return system for a swimming pool?

I have not seen many that work well. Check out several in your area before you buy if you ca find them. I would certainly recommend installing floor returns in your swimming pool. They will help in circulating your chemicals more efficiently, and for colder climates, they help with heating as well. infloorparts.com == == == == == == == == == ==


What is the best location for an air return?

The best location for an air return is a hard a hard question to answer first of all. If you have a forced hot air type of heating, your return has already been chosen for you. If this is a retro fit air system, the return is chosen by the installer. In this situation there is usually space between two ceiling joists that are located at the most central area where he or she can find. With the information given this is the best answer you will probably get