Yes and an air gap for a basin faucet and an air gap located in most dishwasher and washing machines.

The actual size of the air gap is 2 times the effective opening (supply pipe) but in no case less then 1 "

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

How do you attach tubing to faucet in sink?

You don't as it defeats the purpose of the AIR GAP Read your plumbing code


What does AUK air gap stand for?

auk air gap


What is the recommended size for the gap between drywall sheets during installation?

The recommended size for the gap between drywall sheets during installation is typically 1/8 inch.


Design of air gap in dc machines?

Minimum distance of air gap


Why does the air gap leak when you run your dishwasher?

Your air gap is not supposed to leak. Check the hose that leads from the air gap to the garbage disposal for a clog. This should resolve your problem.


What is the resistance of an air gap?

The resistance of an air gap is effectively infinite until it reaches its arcover threshold voltage; then it drops to near zero as the air in the gap ionizes. It returns to effectively infinite when the current through the gap is insufficient to keep the air ionized.


What is the recommended gap between a wall and a vanity during installation?

The recommended gap between a wall and a vanity during installation is typically around 1-2 inches to allow for proper ventilation and access for plumbing connections.


What is air gap on cub cadet front pto clutch?

Prior to installation; using a feeler guage check the clearence between the armature assemble and rotor at 3 evenly spaced locations. There should be a gap of .060 and .125 (1/8 inch. if the gap is exceeded the armature and rotor should be replaced. With the clutch disengaged, using a feeler guage check the clearence (Air Gap) at both access slots between the ears of the brake flang. This must be between .010 and .015. Tighten or loosen the brake flange mounting nuts to obtain the proper air gap.


Why is it important to have an air gap in a water rocket?

Water is non-compressible. The air gap is what allows additional air to be pumped into the rocket.


What is the recommended size for a laminate floor expansion gap to prevent buckling and ensure proper installation?

The recommended size for a laminate floor expansion gap is typically 1/4 inch to prevent buckling and ensure proper installation.


What is Gap's code of Ethics Policy?

Gap's code of Ethics are right here: http://www.itglwf.org/lang/en/documents/GapCodeofConduct.pdf


What is role of air gap?

An air gap is to protect the potable water system from contamination from back syphon and it is the best protection possible as there is nothing mechanical to be tested or able to fail (Air gap water distribution) Air break drainage