answersLogoWhite

0

The total kW load is only a guide to the solar panel capacity. Any energy generated by the solar panel will reduce the energy you draw from the grid, which leads directly to less CO2 output at the power plants. But the power plant is still needed for when there is a cloudy day. When it's cloudy the solar panel output is drastically reduced, although they still produce power, as the salesmen are keen to emphasize, but what they don't tell you is that the power output is reduced by about 95%.

Also, in many countries, if your panels generate excess electricity you sell it back to the grid, so the capacity of the panels is not critical.

User Avatar

Wiki User

10y ago

What else can I help you with?

Continue Learning about Engineering

If 45 amps loads and 20 loads drawing in a two phases services entrance how much current carried neutral wire?

are supplied by circuits on oppsite legs of the service entrance panel . if each load draws 30amps ,what is the current flow in the neutral wire


How do you identify which JPanel type panel caused the event in Java?

I never tried this, but it should work if you get the event source and cast it to a JPanel object. This is what it should look like:JPanel newPanel = (JPanel) event.getSource();What you did is assign the reference of the source panel to a new panel, and now you can go on with your code.


What are the main components of a household circuit?

MAIN COMPONENTS (HOUSE HOLD CIRCUIT)1. METER2. MAIN SWITCH3. PANEL BOARD4. SOCKETS5. LOADS~> C.A.P.T.A.I.N D.A.R.NA ! xD


Does a 60947-3 switch have a breaking capacity?

All switches have a breaking capacity. The number 60947-3 is not a switch number it is an IEC standards publication that relates to panel mounted switches. The publication sets out specifications that manufacturers have to adhere to so as to get their equipment approved for use.


What happens if two 120 volt loads are connected in series to a 240 volts service?

Burn correctly if they were ordinary light bulbs having the same power rating.However, if the loads were different, such as a 100 watt lamp and a 40 watt lamp - neither of them would produce the same amount of light.If the loads were of very different types - say a 120 volt motor, which is a magnetic device, and a 120 volt computer, which is an electronic device - you can't say for sure how well they would each work when connected together in series across a 240 volt service without knowing a lot more facts about them.What happens will always depend on the individual resistances and impedances of each load and how different they are.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.

Related Questions

Can 100 amp distribution panel feed a 70 amp sub panel?

Yes they can. As long as the total load of all subs does not exceed the rated capacity of the main breakers, you should be fine, including 80 percent de-rating of any constant loads.


What kind of flashing should be used on the horizontal seam between two panel siding boards?

The horizontal seam between two panel siding loads should have what flashing?


What size wire should be used for a 60 amp sub panel?

For a 60 amp sub panel, a 6-gauge wire should be used to ensure proper electrical capacity and safety.


Can you use a 200Amp disconect to feed a 100Amp main panel?

No, it is not recommended to use a 200A disconnect to feed a 100A main panel. The disconnect should always be rated equal to or higher than the main panel it is feeding to ensure proper protection and capacity handling. It is important to match the amperage ratings to avoid potential overload and safety hazards.


Can you run 30a per phase on a 100a panel?

No, you should not load a panel beyond its rated capacity. In this case, a 30A load per phase in a 100A panel would exceed its capacity and could cause overheating or other safety hazards. It's important to properly size the panel based on the expected load requirements.


What is the maximum amperage capacity of a 30 amp panel?

The maximum amperage capacity of a 30 amp panel is 30 amps.


How do you calculate the total amps in a breaker panel?

To calculate the total amps in a breaker panel, add up the amperage ratings of all the individual circuit breakers in the panel. This total amperage should not exceed the panel's maximum capacity, which is typically labeled on the panel itself.


What is the maximum amperage capacity of a 50 amp breaker panel?

The maximum amperage capacity of a 50 amp breaker panel is 50 amps.


What is the maximum amperage capacity of a 40 amp sub panel?

The maximum amperage capacity of a 40 amp sub panel is 40 amps.


What is the maximum current capacity of a 100 amp service panel?

The maximum current capacity of a 100 amp service panel is 100 amps.


How can I upgrade my electrical panel?

To upgrade your electrical panel, you should hire a licensed electrician to assess your current panel's capacity and determine the appropriate size for an upgrade. They will then safely install a new panel with the necessary circuit breakers to meet your home's electrical needs.


What size wire should be used for a 100 amp panel?

For a 100 amp panel, a wire size of at least 3 AWG copper or 1/0 AWG aluminum should be used to ensure proper electrical capacity and safety.