RCT is Secondary resistance of Current transformer it depends on Design.
The CL of a current transformer signifies the accuracy class of the transformer. It indicates the maximum permissible error in percentage for a given range of primary current. The lower the CL value, the higher the accuracy of the current transformer. It is important to select a current transformer with an appropriate CL value to ensure accurate measurement and protection in electrical systems.
in welding machine, the transformer used is basically a current transforrmer. so by changing the tap of secondary side of transformer, we can increase or decrease the current in the transformer.
why does have to short-circuit secondary wire of current transformer ?
TPS Class CT is used for transient performance (TP). TPS class Current Transformer has Low Leakage Flux and there is no limit for remanent flux) further there are also TPX,TPY and TPZ class CTs 1. TPX- No Limit for remanent flux due to nil air gap in the core 2. TPY - remanent flux does not exceeded 10 % due to less air gap in the core 3. TPZ- Having practically null remanent flux because there is large air gap is provide in the Core Er. Anil Prajapati, Protection Engineer,Jaipur RVPNL
don't worry
RCT is Secondary resistance of Current transformer it depends on Design.
The CL of a current transformer signifies the accuracy class of the transformer. It indicates the maximum permissible error in percentage for a given range of primary current. The lower the CL value, the higher the accuracy of the current transformer. It is important to select a current transformer with an appropriate CL value to ensure accurate measurement and protection in electrical systems.
Leakage reactance is useful for limiting the short circuit current in transformer and generators. therefore normally the reactance of transformer varies for 4.5% for distribution transformer to 12.5% for 400KV class.
These are the Class codes for CTs used for protection purposes.
CL of a CT is its accuracy class.. it is an approximate measure of the CT's accuracy. e.g. The ratio (primary to secondary current) error of a Class 1 (CL:1.0) CT is 1% at rated current
in welding machine, the transformer used is basically a current transforrmer. so by changing the tap of secondary side of transformer, we can increase or decrease the current in the transformer.
why does have to short-circuit secondary wire of current transformer ?
The difference between current transformer and potential transformer is that the secondary of a current transformer can not be open circuited while under service whereas that of the potential transformer an be open circuited without any damage to the transformer.
It is a transformer with No load attach to it.
A current transformer is primarily used at the neutral point of a transformer for earth fault protection. A neutral current transformer will measure any ground fault current which will essentially flow from the star point of the transformer. A fault-detection device other devices is connected to the current transformer and, if the fault current exceeds a certain trigger value, the fault-detection device will give a trip command to an earth-fault relay to disconnect the supply of electricity to the transformer.