You might have heard about the open or closed loop system.

If it is a closed loop system, then it is referring to the continuous piping loops that are set underground. These loops are to be filled with an anti-freeze-like liquid which is the key to transforming the floor temperature into the geothermal heat pump.

User Avatar

Wiki User

7y ago

What else can I help you with?

Related Questions

What kind of material is used in the waterless ground loop in a waterless earth-coupled closed-loop geothermal heat pump system?

A waterless ground loop in a waterless earth-coupled closed-loop geothermal heat pump system typically uses a high-density polyethylene (HDPE) pipe. HDPE is a durable material that is resistant to corrosion and provides good thermal conductivity, allowing for efficient heat transfer between the ground and the heat pump system.


How does a heat pump resemble a refrigerant system?

A heat pump and a refrigerant system both use refrigerant to transfer heat. The refrigerant absorbs heat from one area (such as indoors in a heat pump) and releases it in another area (such as outdoors in a heat pump). The main difference is that a heat pump can both heat and cool a space, while a refrigerant system is typically used for cooling only.


Can you pump down a heat pump system in heat mode just as you would do in the cool mode?

No, the energy in a heat pump system must be transfered to another heat pump system because the first law of thermodynamics say that energy cannot be created nor destroyed


What kind of Pipe for closed loop heat pump?

heavy gauge copper


When heat is added to a closed system it goes into?

The added heat in a closed system increases the internal energy of the system, which can result in an increase in temperature, pressure, or volume depending on the type of system and the material properties.


What is the heat pump equation used to calculate the efficiency of a heat pump system?

The heat pump equation used to calculate the efficiency of a heat pump system is the Coefficient of Performance (COP) formula, which is the ratio of the heat output to the work input. It is expressed as COP Qh / W, where Qh is the heat output in watts and W is the work input in watts. A higher COP value indicates a more efficient heat pump system.


Can a heat pump thermostat be used on non heat pump air conditioning system?

yes it can but everytime you want heat you have to put it on Emergency Heat..


Why is a replenishing pump mecessary in closed loop hydrostatic circuit?

you need replenishing pump in closed loop hydrostatic transmission is following reason 1)for leakage compensation in the hydrostatic transmission system 2)to reduce heat of the system by adding new volume of relatively cool hydraulic fluid into the system. for further details contact Ramakrishnan IIT madras ramakrishnanphd@gmail.com


What is the difference between heat engine and heat pump?

Heat Engine is the system that converts the Heat energy into mechanical work while Heat pump converts the work into heat


What is a closed system in thermodynamics?

A thermodynamically closed system is one where no mass enters or leaves the system. That does not preclude the possibility of heat or work entering or leaving the system.


What is the role of the outdoor thermostat in a heat pump system?

The outdoor thermostat in a heat pump system helps regulate the system's operation based on the outside temperature. It ensures the heat pump runs efficiently by adjusting the heating or cooling output according to the outdoor conditions.


Does pressure cause heat in a closed system?

In a closed system, pressure can cause heat through a process called adiabatic heating. This occurs when the pressure of a gas in the system increases, leading to an increase in temperature without any heat being added or removed from the system.