answersLogoWhite

0

What else can I help you with?

Related Questions

How does magnetic contactor operate?

explain me about the contactor works with examples. if i want to control a motor with contactor. and how i can use contactor in loops with over load and circuit breakers.


What are the types of coupling in software engineering?

control coupling content coupling common coupling data coupling external coupling message coupling


How do you calculate contactor capacity of star contactor?

metres


What are types of mechanical coupling?

There are many like flexible coupling, jaw coupling, sleeve coupling, tire coupling, pin and bush coupling, rigid coupling, etc


What is the difference between an definite purpose contactor and a lighting sontactor?

A definite purpose contactor is designed (and rated) for a specific load. So a lighting contactor is one example of a definite purpose contactor. A motor starter contactor is another example. So, a lighting contactor is a definite purpose contactor, but a definite purpose contactor is not necessarily a lighting contactor (it might be a motor starter, for instance).


Can you use an AC contactor in the place of DC contactor?

No, you definitely cannot.


Can you replace a 50 amp contactor with a 40 amp contactor?

Replacing a 50 amp contactor with a 40 amp contactor is not advisable, as the 40 amp contactor may not be able to handle the load safely. This could lead to overheating, failure of the contactor, or potential damage to the connected equipment. It's essential to match the contactor's rating to the load requirements for safe and reliable operation. Always consult with a qualified electrician for such replacements.


Which coupling gives the higher gain in case of amplifier - a Capacitor coupling b Impedance coupling c Transformer coupling?

transformer coupling


Definition of coil in contactor?

The coil in a "Contactor" is essentially an electromagnetic coil that provides the driving force to close the contacts in a Contactor. When the "Coil" is energized by a lower control voltage usually from some type of controller such as a PLC, the Normally-Open contactor will close or in the oposite case, the Normally-Closed contactor will open.


How is a Blowout coil connected?

A blowout coil connected in series with contactor's auxiliary contacts that shunt around the main contactor contacts. The coil is out of the circuit when the main contactor contacts are closed and in the circuit when the main contactor contacts are open.


How many wires to control a mechanically held contactor?

A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.


What is RC coupling?

rc coupling is a coupling that involves capacitor aand resistor