A 'pressure coil' is an archaic term for a 'voltage coil' (UK terminology) or 'potential coil' (US terminology), as opposed to the 'current coil' in a wattmeter. This coil is connected in parallel with the supply, while the current coil is connected in series with the load.

User Avatar

Wiki User

12y ago

What else can I help you with?

Continue Learning about Engineering

How is a watt meter connected?

There are two coils in watt meter namely current coil & potential coil.the two ends of current coil are 'M' & 'L' and they should connect in series with instrument. and the two ends of p.c. is 'c' which is connected to 'L'. and another is at the other end of instrument.There are two coils in watt meter namely current coil & potential coil.the two ends of current coil are 'M' & 'L' and they should connect in series with instrument. and the two ends of p.c. is 'c' which is connected to 'L'. and another is at the other end of instrument.There are two coils in watt meter namely current coil & potential coil.the two ends of current coil are 'M' & 'L' and they should connect in series with instrument. and the two ends of p.c. is 'c' which is connected to 'L'. and another is at the other end of instrument.


Why is the electric watt meter connected in series with the rest of the circuits in the house?

First of all, you are referring to an energy meter, not a wattmeter. A wattmeter measures power, in watts, whereas an energy meter reads energy, in watt hours (or, more specifically, kilowatt hours). The energy company bills you for energy, not power.Having said that, the connections each instrument are the same. In fact, there are two coils inside an energy meter: a current coil, and a voltage (or potential) coil. The current coil is connected in series with the load while the voltage coil is connected in parallel with the supply voltage.The current coil measures the in-phase component of the current drawn by your load, so that the instrument always reads the true power (multiplied by time -the function of the aluminium disc) of the load -i.e. not the apparent power or reactive power.


Does watt meter reading go negative?

Yes!


Why pt coil is not present in three phase watt meter?

A three phase watt meter's potential transformer and current transformer are located remotely from the metering cabinet. On large size bus installations it would be impossible to take the bus bars to the meter so it is done the other way around. Leave the Ct's and Pt's on the bus bars and use smaller wire to feed the meter in a remote accessible location. The utility company requires a metering cabinet over certain voltages and amperage be accessible to the meter reader. In some installations the metering cabinet is installed remotely on the outside of the building away from the electrical room.


What is the difference between single phase and three phase voltage measurement?

Phasing, or the number of phases in an electrical system has nothing to do with the voltage. A single phase and three phase supply could have a voltage supply of any given voltage from virtually 0 to infinity. Most single phase power supplies in the US are 120/208-240 volt. Three phase power supplies are typically 120/208 to 277/480 volt.

Related Questions

In watt meter why pressure coil has more turn than current coil?

In an analog induction type wattmeter the pressure coil is connected accross the voltage source.It is intentionally made to have a larger number of turns than the current coil so that it's impedence increases and it draws minimum current from the circuit; causing lesser error in the reading.


Can you connect pressure coil instead of current coil in watt meter to measure power?

You have to connect both coils to measure power: the current coil in series with the load, and the voltage ('pressure') coil in parallel with the supply. And you have to observe the wattmeter's polarity markings if you don't want it to read downscale (backwards)!


How do you interchange connection of watt meter in 3 phase induction motor loading when it shows negative deflection?

interchange connections of c and v i.e pressure coil


Can watt meter negative reading?

Yes. This is usually an indication that either its current coil or its voltage coil has been wired incorrectly.


What is the function of watt meter?

The wattmeter is an instrument to measure the electrical power.


How is a watt meter connected?

There are two coils in watt meter namely current coil & potential coil.the two ends of current coil are 'M' & 'L' and they should connect in series with instrument. and the two ends of p.c. is 'c' which is connected to 'L'. and another is at the other end of instrument.There are two coils in watt meter namely current coil & potential coil.the two ends of current coil are 'M' & 'L' and they should connect in series with instrument. and the two ends of p.c. is 'c' which is connected to 'L'. and another is at the other end of instrument.There are two coils in watt meter namely current coil & potential coil.the two ends of current coil are 'M' & 'L' and they should connect in series with instrument. and the two ends of p.c. is 'c' which is connected to 'L'. and another is at the other end of instrument.


Why are the M and C terminals of a watt meter short circuited?

In a watt-meter there are four terminals: M,L which are the current coils and C,V which are called as pressure coils . . To measure the current the measuring instrument should be placed in series with the load but in case of voltage, the instrument should be connected in parallel to the load . . therefore M from the current coil and C from the pressure coil are can be short-circuited to measure the power of the given circuit. by hameed khan md, hyderabad e-mail:hameed.shonnu@gmail.com THANK u


What are the types of electrodynamometer?

The two main types of electrodynamometer are attracted disc type and moving coil type. In the attracted disc type, two stationary coils create a magnetic field that attracts a disc attached to the moving coil. In the moving coil type, the coil is suspended between stationary magnets and experiences a force when current flows through it.


How many voltmeter and ammeter are in dc watt meter?

There is no volt meter or amp meter in a DC watt meter.


Why is the electric watt meter connected in series with the rest of the circuits in the house?

First of all, you are referring to an energy meter, not a wattmeter. A wattmeter measures power, in watts, whereas an energy meter reads energy, in watt hours (or, more specifically, kilowatt hours). The energy company bills you for energy, not power.Having said that, the connections each instrument are the same. In fact, there are two coils inside an energy meter: a current coil, and a voltage (or potential) coil. The current coil is connected in series with the load while the voltage coil is connected in parallel with the supply voltage.The current coil measures the in-phase component of the current drawn by your load, so that the instrument always reads the true power (multiplied by time -the function of the aluminium disc) of the load -i.e. not the apparent power or reactive power.


What is the MKS unit of pressure?

The MKS (meter-kilogram-second) unit of pressure is the pascal (Pa), which is defined as one newton per square meter.


Why you reset the zero point on the watt meter?

So that the result that you find on the watt meter after resetting it will be accurate