Higher capacity (higher KW rating) motors take huge starting current to get over the starting torque. To avoid the high inrush of current, star delta starter is used. When started, the motor gets connected in star for few seconds and switches over to Delta and continues to run in delta. In this case motor is designed to run in Delta.
To terminate a 3 wire wye motor to a 3 phase delta connection you need a 3 phase transformer to convert from delta to wye. Do not lift the common neutral connections inside the motor and rewire for delta, because the voltages will be wrong.
Show digram 3 phase motor 110 and 220
A three-phase motor will not start if one or two phases aren't connected. If while running one or two phases "drop out", it will continue to run for awhile, but will eventually burn out, unless connected to a motor saver.
Most likely is going to explode. Put 120 psi on a car tire rated for 35psi and you will have the same effect.AnswerThe circuit's protective device will disconnect the motor from the supply, It will not explode!
Star (or wye) connection is where each of the three phases has a fourth conductor, neutral, as its current return. Current flow in this configuration is phase to neutral, which is also grounded back at the distribution center. There will be five total connections, phase A, B, and C, neutral, and (protective earth) ground. Delta connection is where each of the three phases uses the prior phase as its current return. Current flow in this configuration is phase to phase, and there is no neutral, though there is still a ground. There will be four total connections, phase A, B, and C, and (protective earth) ground.
Star and delta connection
A connection of a contactor to three phase motor.
To terminate a 3 wire wye motor to a 3 phase delta connection you need a 3 phase transformer to convert from delta to wye. Do not lift the common neutral connections inside the motor and rewire for delta, because the voltages will be wrong.
Show digram 3 phase motor 110 and 220
To change the connection of a single-phase line to a three-phase line for a DC motor, typically you would need to use a phase converter or a variable frequency drive (VFD) to convert the power supply. This will allow you to provide the necessary three-phase power to the DC motor for it to operate efficiently and safely. It's important to consult with an electrician or engineer to ensure the proper conversion is done based on the motor specifications.
A three-phase motor will not start if one or two phases aren't connected. If while running one or two phases "drop out", it will continue to run for awhile, but will eventually burn out, unless connected to a motor saver.
Typically, an 18KW motor would be too large to be single phase because then the windings' conductors will be too large inorder to carry such high currents. I,myself,don't think such a motor exist since a cheaper 3phase motor could be used instead.
when starting a 3 phase induction motor,first start with star connection,because reduced current is being applied and after start change it to delta connection then. full line current is applied to the motor.
Most likely is going to explode. Put 120 psi on a car tire rated for 35psi and you will have the same effect.AnswerThe circuit's protective device will disconnect the motor from the supply, It will not explode!
No. That would be a single phase motor.
Star (or wye) connection is where each of the three phases has a fourth conductor, neutral, as its current return. Current flow in this configuration is phase to neutral, which is also grounded back at the distribution center. There will be five total connections, phase A, B, and C, neutral, and (protective earth) ground. Delta connection is where each of the three phases uses the prior phase as its current return. Current flow in this configuration is phase to phase, and there is no neutral, though there is still a ground. There will be four total connections, phase A, B, and C, and (protective earth) ground.
To use a single/one phase motor instead of a three phase motor is possible if you have a three phase power supply as you will only need to tap one of the three phases together with neutral and an earthwire, however to use a three phase motor instead of a single phase will require the provision of three phase power supply.