Blowdown Valves
In case of Transformer oil the meaning of BDV is break down voltage. It refers to the one of the tests of the oil.
The minimum Breakdown Voltage (BDV) of transformer oil required typically varies based on the voltage level of the transformer. For 11 kV transformers, a minimum BDV of around 30 kV is usually acceptable. For 66 kV transformers, a BDV of approximately 50 kV is often required, while for 132 kV transformers, it should be at least 60 kV or higher. Ensuring adequate BDV is crucial for the insulation performance and reliability of the transformer.
to cool a winding of transformer and it is a insulating material and transformer oil is a purifing oil
Nytro libra is an uninhibited transformer oil
transformer consists of polychlorinated biphenyls,...etc
The oil level indicator in a transformer is used to show the oil level.
The minimum Breakdown Voltage (BDV) of transformer oil required typically varies based on the voltage level of the transformer. For 11 kV transformers, a minimum BDV of around 30 kV is usually acceptable. For 66 kV transformers, a BDV of approximately 50 kV is often required, while for 132 kV transformers, it should be at least 60 kV or higher. Ensuring adequate BDV is crucial for the insulation performance and reliability of the transformer.
It is better to check the BDV (Break down voltage) of the oil to decide whether the said oil is usable for 11KV application, instead of depending upon its "expiry" date.
The BDV value of the transformer oil should be above 50kv winding resistance value should me minimum depends upon the KVA Of trans earthing should be provide for the trans air should be release inside of the tranformer insulation level should be check to operate the transformer these are all the initial condition to operate the trans
The BDV (Breakdown Voltage) value of engine oil measures its dielectric strength, indicating how well the oil can insulate and resist electrical breakdown. A higher BDV value signifies better quality and performance, as it can help prevent the formation of sludge and ensure effective lubrication under high temperatures and pressures. Typically, BDV values for engine oils should be above 30 kV to ensure proper functionality and longevity. Regular testing can help monitor the oil's condition and its ability to protect engine components.
Transformer oil is pure insulating oil.
above thirty (30) KV (rms)
to cool a winding of transformer and it is a insulating material and transformer oil is a purifing oil
Nytro libra is an uninhibited transformer oil
B.I.L. stands for Basic Impulse Level for the transformer. It should be on the faceplate of the transformer.
An oil transformer is filled with PCB oil to better transfer heat from the windings to the outside case (and into the air).
transformer consists of polychlorinated biphenyls,...etc
When you say BDV you might mean the dielectric strength of transformer oil. A new transformer oil should have at lest a dielectric strength of 39 KV. from a British standard.Transformer oils used are normally tested using ASTM D877-82 with the KV strength tester using 1" electrodes spaced 0.1" apart and the test voltage increased at 3,000 volts/min until it breaks down. The average Kv obtained after 8 trials is considered the Oil dielectric strength.Using this test method,dielectric strength at 30 kv and above is considered good. Dielectric strength between 23 to 29Kvis considered usable, but requires filtering. Below 23 kv, the transformer oil should be replaced.Another method ASTM D18747-82 uses the small radius electrodes but spaced only .o4 inches. The test voltage is 500volts/min and increased until breakdown. The dielectric strength is still the average Kv obtained in 8 trials. The dielectric strength of 28-29Kv is considered good. Below 28 kv, the transformer oil is usable but requires filtering. The latter method is considered a better test method