How to calculate transformer core loss and iron loss?

there are several losses in a transformer that prevent it from attaining 100% efficiency. One is core loss, which can be divided into Hysteresis losses, Eddy currents and Magnetostriction loses. see for more details http://en.wikipedia.org/wiki/Transformer#Energy_losses


How many 200 amp panels can you tap off 250 kva transformer?

You can tap off approximately 833 200 amp panels from a 250 kVA transformer. This calculation is based on dividing the kVA rating of the transformer by the current rating of the panel.


What is the result when 3 kva power requirement is being supplied by 250 kva transformer?

The result is that the transformer runs cool and contented. The '250 KVA' rating on the transformer is its maximum ability to transfer power from its input to its output without overheating, NOT an amount of power always running through it. If the 3 KVA load happens to be the only thing connected to the transformer at the time, then only 3 KVA flows into the transformer from the primary line, and only 3 KVA leaves the transformer secondary.


How many amps will a 250 kVA transformer in 220 volts secondary?

To calculate the amperage in the secondary side of a transformer, you can use the formula: Amps = kVA / (Volts x Sqrt(3)). For a 250 kVA transformer with a 220-volt secondary, the amperage will be approximately 660.4 Amps.


Why transformer are rated in kVA instead of KW?

Transformers are rated in VA or kVA. That is because the voltage is limited by the power loss in the magnetic core, and the current is limited by the power loss in the resistance of the windings. The rated voltage times the rated current gives the transformer's rating in kVA.


For 250 KVA transformer how many KVAR to be paralleled for no load loss?

No load losses are real power losses (in watts, not vars), so I'm not sure what you're talking about. If you're trying to parallel a transformer with another one to try to cancel out no load losses, you can't do this. These losses are also called core losses and are the price you pay to energize a transformer.


What is the difference between a 1.5KVA and a 3KVA transformer?

The 3 kVA transformer will weigh double the 1.5 kVA transformer.


If power factor is 8 then how many ampere there will be in each phase of a 250 kva transformer?

The power factor is only taken into consideration when the Kilowatts of a transformer is used.


What is the full load loss of a 630 kva distribution transformer?

Much to my dismay i found its an experimental value, depends on type of core, cooling tech, resistance of wiring etc.


What is mean KVA Rating of transformer?

copper loss is directly propostional to I (AMPERE) and iron loss directly propostional to V (VOLTAGE) then total losses is equal to volt ampere hence the rating of transformer in KVA. SULTAN


What is the KVA rating required of the testing transformer?

Depends on the kva rating of the devices to be tested using a transformer.


How do you earth in the 1600 kva transformer?

In 1600 kva transformer we provide NGR (Neutral grounding resistance)