In a heat pump system, the suction-line drier should be placed on the suction line, typically between the evaporator and the compressor. This location allows the drier to effectively remove moisture and contaminants from the refrigerant before it enters the compressor, protecting the compressor and ensuring efficient operation. Proper placement is crucial for maintaining system performance and longevity.

User Avatar

AnswerBot

2mo ago

What else can I help you with?

Related Questions

Where must a suction-line drier be placed in a heat pump after a motor burnout?

between the comp and the reversing valve


Where must a suction line drier be placed in a heat pump after a motor burnout?

Between compressor suction and reversing valve,also called true suction.


Where must a suction - line drier be placed in a heat pump after a motor burnout?

Between compressor suction and reversing valve,also called true suction.


Where must a suction line drier be placed in a heat pump t?

In a heat pump system, the suction line drier should be placed on the suction line, typically between the evaporator and the compressor. This positioning helps to remove moisture and contaminants from the refrigerant before it enters the compressor, ensuring optimal performance and preventing damage. It's crucial to install the drier in a location that allows for easy access for maintenance and replacement.


How can a heat pump filter drier be differentiated from a standard filter drier?

A filter drier for a cooling only condensing unit will have an arrow pointing in one direction. This is because the refrigerant that passes through it will always flow in the same direction. A heat pump filter drier must have the ability to allow the refrigerant to flow through it in either direction and so a filter drier that is made for a heat pump will have two arrows pointing in opposite directions.


Where must a suction line be placed in a heat after a motor burnout?

between the comp and the reversing valve


Where must a suction line be placed in a heat pump after a motor burnout?

between the comp and the reversing valve


What location must a check valve be placed?

Generally, placed close to the supply discharge of the pump.


What is depicted below and what must a drier do when they approach it?

It seems that there is no image or specific content provided for me to analyze. However, if a drier approaches a potentially hazardous situation—such as a wet or slippery area—they must exercise caution, assess the surroundings, and adjust their methods to ensure safety, such as reducing speed or using appropriate footwear to prevent accidents.


What must be present for heat to occur?

there must be atom and molecule movement for heat and a suitable environment for heat to grow, such as, it should already be hot where the heat is occurring


What must happen to heat to be transferred to convection?

the liquid or gas must circulate to move the heat.


If PHIPII is placed on a shared folder what must individuals have in order to access the folder?

If PHI/PII is placed on a shared folder, what must individuals have in order to access the folder?