Becomes an air bound waste

User Avatar

Wiki User

16y ago

What else can I help you with?

Continue Learning about Engineering

What causes water to rise into the other side of a double sink?

The drain going out is clogged. Both sides share the same drain and water seeks it's own level so it comes up in the other side. Put some drain cleaner down the drain.


Can you install a shower drain without a pan liner?

Yes, you can install a shower drain without a pan liner, but it's generally not recommended. A pan liner helps prevent water from seeping into the subfloor, which can lead to mold and structural damage. If you choose to proceed without one, ensure that the substrate is waterproofed adequately and that the drain is installed properly to minimize the risk of leaks.


What are all the methods to trapping co2?

Some methods of trapping carbon dioxide are: electrochemical reduction, cooling it into a liquid, and passing the gas through an alkali.


Can you attach abs drain pipes to execting copper drain pipes for a double sink?

It is tricky but u can with a fernco if the copper dwv drain line is 1 1/2" in diamater use a 1 1/4" x 1 1/2" reducing fernco because the outside diamater of copper is smaller than abs or PVC


Why does the water from the disposal side of the double sink drain into the dishwasher?

Probably the drain hose from the dishwasher isn't high enough to keep the water from running back . The hose should be above the level of the disposal at some point. Some states require an "air gap" which is a device that is placed in the drain line to prevent this. Some states require a simple high loop in the drain hose. Many dishwasher manufacturers are now installing backflow preventers in the dishwasher.

Related Questions

What is the recommended height of a kitchen drain from the floor?

The recommended height of a kitchen drain from the floor is typically around 18 to 20 inches.


What is the recommended size for a sink drain pipe?

The recommended size for a sink drain pipe is typically 1.5 to 2 inches in diameter.


If you cut the old cast iron shower drain above the trap to move the drain with PVC would it be wrong to put a 2nd trap under the new drain?

It might work (poorly) for a while, but virtually every plumbing code prohibits "double trapping" such as this because eventually they will plug up because you have seriously impeded their "self-scouring" capability. And screwed up their vent.


What is the recommended drain height for a vanity installation?

The recommended drain height for a vanity installation is typically around 18 inches above the finished floor level.


What is the recommended height for a vanity drain installation?

The recommended height for a vanity drain installation is typically around 18 inches above the finished floor level.


What is the recommended rough-in height for a vanity drain?

The recommended rough-in height for a vanity drain is typically around 18 inches above the finished floor level.


What is the recommended depth for installing a rough-in for a toilet drain?

The recommended depth for installing a rough-in for a toilet drain is typically around 12 inches from the finished floor level.


What is the recommended height for a sink drain in a kitchen or bathroom?

The recommended height for a sink drain in a kitchen or bathroom is typically around 18 to 20 inches above the floor.


What is the recommended diameter for a 2 inch drain pipe in a residential plumbing system?

The recommended diameter for a 2-inch drain pipe in a residential plumbing system is typically 2 inches.


What is the recommended diameter for a 4 inch drain pipe in a residential plumbing system?

The recommended diameter for a 4 inch drain pipe in a residential plumbing system is typically 4 inches.


What is the recommended drain pipe size for a residential kitchen sink installation?

The recommended drain pipe size for a residential kitchen sink installation is typically 1.5 to 2 inches in diameter.


What is the recommended washer drain height for proper installation and functionality?

The recommended washer drain height for proper installation and functionality is typically around 30 inches above the floor level.