answersLogoWhite

0

To minimize sweating of the air around the pipe. When the air comes in contact with a cool surface, its water vapor condenses!

User Avatar

Wiki User

17y ago

What else can I help you with?

Continue Learning about Engineering

How do you determine what suction pressure should be in R22 air conditioning compressors suction line?

The proper suction pressure of any air conditioning or refrigeration system is determined by the type of refrigerant used and sometimes the amount of charge. : Suction pressure used is also directly related to the temperature required. : The temperature required in the evaporator relates to the pressure required in the suction line since, the fluid is at saturation in the evaporator. : Knowing the temperature required, use the fluid's saturation tables to find the corresponding pressure required.


What is the difference of earth and insulated return in an electrical system?

An earthing system is a system where circuits are connected by a ground. An insulated return system is how power is transferred to trains.


Why an engine is not used in place of an expansion valve in a vapor compression refrigeration cycle?

An engine cannot replace an expansion valve in a vapor compression refrigeration cycle because their functions are fundamentally different. The expansion valve is designed to reduce the pressure of the refrigerant, allowing it to expand and cool before entering the evaporator. In contrast, an engine converts thermal energy into mechanical work, which would not facilitate the necessary pressure drop or temperature reduction required for effective refrigeration. Additionally, using an engine would complicate the system and introduce inefficiencies that could hinder cooling performance.


Why do the pipes in a steam heating system need to be insulated?

The pips in a steam heating system need to be insulated to prevent condensation. Condensation can lead to mold and or freezing of the steam pipes in the winter.


What causes low suction in an hvac-r system?

blocked condenser

Related Questions

What are the disadvantages of vapour compression refrigeration system?

Disadvantages of vapor compression refrigeration system include potential leaks of refrigerant gases, environmental impact of fluorinated gases, energy consumption for compression, and complexity of maintenance and repairs.


Is suction pressure is high side or low side of refrigeration system?

Low side.


When a refrigeration system is operating normally with a 70 PSIG suction pressure and a 240 PSIG discharge pressure the compression ratio is A. 3.75 to 1. B. 3 to 1. C. 2.5 to 1. D. 3.5 to?

c


What did Ferdinand Carre invent in 1858?

He invented the ammonia vapor-compression system used in refrigeration.


How do you get the h2 in compression-vaporization refrigeration system?

To get the h2 in a compression-vaporization refrigeration system, you would typically use a refrigerant such as R-134a or R-410a, which contains H2 molecules. The refrigerant circulates through the system, undergoing phase changes and absorbing heat from the surroundings, enabling the system to cool the desired space.


Why compressor suction line ice forming in a refrigeration system?

Ice formation on the suction line of a compressor in a refrigeration system is typically caused by a combination of low refrigerant levels, poor insulation on the suction line, or a malfunctioning expansion valve. This results in the refrigerant temperature dropping below the dew point, causing moisture in the air to freeze on the suction line. It is important to address the root cause to prevent further issues with the system.


What will happen if there is moisture in refrigeration system?

1.It can enters to the compressor through suction line and can damages the parts of the compressor.2.it can carry out


What is refrigeration effect?

When you plot a system on a mollier diagram it the point between the pressure drop and the bottom of the compression line, measured in BTU/LB. Also known as the Net Refrigeration Effect.


Why COP is used for evaluation of compression refrigeration system but not absorption refrigeration system?

Coefficient of Performance (COP) is used for evaluating compression refrigeration systems because it reflects the cooling capacity of the system relative to the work input required to operate it. In absorption refrigeration systems, the performance is typically evaluated using the Coefficient of Performance (COP) or the Coefficient of Performance relative to the heat source (COP_Φ) since these systems use heat energy, rather than mechanical work, to operate.


How do you improve the performance of vapor compressor refrigeration cycle?

In practical applications, vapor-compression refrigeration systems are the most commonly used refrigeration systems, and each system employs a compressor. In a basic vapor compression refrigeration cycle as shown in Figure 3.28, four major thermal processes take place as follows: • evaporation, • compression, • condensation, and • expansion.


Why discharge refrigeration gas admit to doom of a rotary refrigeration compressor?

The refrigeration system used in air conditioners with rotary compressor, the discharged gas is entered firstly into the doom of the compressor, while the system used with reciprocating and other compressors, it is admitted into the discharge tube. and are suction cooled. Why in rotary systems, the discharge refrigerant directly admit into the doom first.


What is a generator in vapor absorption refrigeration system?

The generator in a vapor absorption system for a refrigerator consists of all of the components that make the refrigerator work. The system allows for compression, condensation, evaporation, and expansion.