What is Difference between relief valve and safety valve?

Relief valve always position in the suction line in oreder to relief the extra pressure, while safety valve is always placed at discharge line to release excess pressure.I would take that one step further by stating that a " RELIEF VALVE" is one that is "meant" to be lifted off its seat, as opposed to a "SAFETY RELIEF VALVE" which is not!DIFFERENCE BETWEEN RELIEF VALVE AND SAFETY VALVE:1. Releif valve is applicable in the fluid system.safety valve is applicable in the gaseous system.2.Relief valve opening is directly proportional to the pressure rise.Safety valve opening is will happen at after reaching the setpressure.3.Mode of relif vlave line is again connected to the suction.But in the safety valve is just vent-out there is no connection tosuction.


What does converter relief valve do?

Converter relief valve ensures high line pressure does not flood/overrun the solenoid.


Where is the only true suction line?

The line coming from the Discharge Line, which comes from the Compressor into the 4-Way Valve


Where must a suction line drier be placed in a heat pump after a motor burnout?

Between compressor suction and reversing valve,also called true suction.


Where must a suction - line drier be placed in a heat pump after a motor burnout?

Between compressor suction and reversing valve,also called true suction.


What temperature difference should be expected between the indoor line and the permanent suction -line ports on the reversing valve during the cooling cycle?

During the cooling cycle, a temperature difference of around 18-20°F is expected between the indoor suction line and the permanent suction line ports on the reversing valve. This temperature difference indicates proper operation of the system.


Where must a suction line be placed in a heat after a motor burnout?

between the comp and the reversing valve


Where must a suction line be placed in a heat pump after a motor burnout?

between the comp and the reversing valve


Where does the phial position for a thermostatic expansion valve?

The phial of a thermostatic expansion valve is typically positioned on the suction line downstream of the evaporator coil. It is important for the phial to be securely clamped to the suction line to accurately sense the temperature of the refrigerant leaving the evaporator.


Where must a suction-line drier be placed in a heat pump after a motor burnout?

between the comp and the reversing valve


Can a hot water heater pressure relief valve drain into a sewer line?

Not directly.


What are the possible causes of freeze up of tubing from expansion valve to suction line?

Low airflow, low refrigerant or restriction