the C.B operation depends upon relay senses. in realy their is trip coil.

when ever fault occurs then change in c.t occures[current varies] due to that secondary current in c.t changes then magnetising field of trip coil is varies and then relay contacts open then c.b contacts open..........this is the impotance of TRIP COIL

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

When a shunt trip breaker trips does the voltage remain on?

No, it does not have voltage in trip position.


How much does a shunt trip breaker cost?

The cost of a shunt trip breaker depends on the amperage and number of poles the circuit connected to it needs. The cost of the shunt trip over a conventional breaker is substantially more.


Can you show me shunt trip diagram?

A shunt trip diagram typically illustrates the electrical connections and components involved in a shunt trip circuit, which is used to remotely trip a circuit breaker. It includes elements like the circuit breaker, shunt trip coil, power source, and control switch. The diagram shows how the control switch activates the shunt trip coil, causing the breaker to open and interrupt the circuit. For a specific diagram, it's best to refer to technical manuals or manufacturer specifications.


Why use shunt release in circuit breaker?

A secondary shunt releases (extra trip coil) is used forelectrical tripping of the circuit breaker by protectiverelays or manual control devices when more than onetrip coil is required.


Does a shunt trip breaker work from a dry set of contacts?

Yes, but you need a power source, for the shunt trip coil voltage, in the circuit.


If a shunt trip occurs does breaker go to off or trip position?

When a shunt trip occurs, the breaker typically goes to the "trip" position, which indicates that the circuit has been interrupted and the contacts are open. This allows for quick identification of the issue and isolation of the circuit for safety reasons.


How do you reset a shunt trip breaker?

A shunt trip breaker is reset the same way as an ordinary breaker, move the handle to the full off position and then to the full on position. First check the tripping circuit, sometimes a latch relay is used to hold the breaker shunt trip coil in the trip position. If this is the case then reset the latch relay first.


Where do you connect the white wire from the shunt breaker?

Connect to the circuit neutral wire which should also be white.


How do you hook up wire from ansul system to shunt trip breaker?

You would need to take the "input" wire for the shunt trip breaker to an electrical switch (not alarm initiating switch, which are DC voltage rated) within the Automan unit and connect to the "Common" connection and the "return", the wire to the actual shunt circuit of the breaker, from the "Normally Open" connection of the switch. When the unit activates, the switch will be placed into "Closed" position, therefore completing the circuit and activating the shunt coil.


Why shunt resistance is connected in the parallel?

Shunt means parallel only..................


How does a shunt trip relay work?

A shunt capacitor creates a low resistance path in a circuit so that electricity can pass around to another point. Shunt capacitors create shorts when they receive abnormally high amounts of voltage to correct series circuits.


Can a shunt trip breaker be tripped from to different emergency buttons?

Yes a shunt trip breaker can be activated manually.