A GFCI outlet or breaker is designed to measure the current flow on both the hot and neutral wires connected to it. A "trip"will occur whenever the is a 5mA(millamp) difference between the two currents. Examples would be when you drop a hairdryer into water allowing power to flow through the water and not through the wires correctly. This system is designed as a life safety system to stop power from flowing through a person in case of an accident like the one I described.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Engineering

Will starting current on a motor trip a gfci breaker?

A GFCI measures difference in output to return current. A Overload breaker in your panel is what trips from too much current. many are time delay and will not trip immediately from the less than a second of start up current spike.


Why does your protective device keep tripping out?

Because something is wrong. Check for shorts and, if it is a GFCI, also check for ground faults and leakages. It is also possible, in the case of a GFCI, that an inappropriate load, such as a computer monitor or UPS, is connected. These devices pull transient power to ground and will trip a GFCI. Do not ignore the situation. The protective device is tripping for a reason.


What is a Class A circuit breaker?

A Class "A" Circuit breaker is a Ground Fault Interrupt (GFI or GFCI) breaker ."Class A" marking -- A "Class A" ground-fault device is intended to protect people. The Class A marking indicates that the trip threshold of the GFCI is between 4 mA and 6 mA. This marking may be in any location except the back.


How does a ground fault circuit interrupter shuts down a circuit?

A ground fault circuit breaker detects leakage current between the hot wire coming off the breaker and the neutral/ground since the neutral is bonded to the ground in the panel, if it senses a current of 6 milliamps or more it will trip. Note: no sharing of the neutral for a circuit on a ground fault breaker If a few milliamps from the hot (black) wire do not return on the neutral (white) wire, then a GFCI assumes that current it traveling harmfully elsewhere through your body. So it disconnects. A GFCI can monitor 15,000 milliamps. But if only 5 go missing, then a GFCI trips.


Why the slope of voltage-resistance characteristic increases in the case of tungsten lamp and decresing in case of carbon lamp?

If the filament really was made from a material that has a negative temperature coefficient (as temperature increases, resistance decreases) then the decreasing resistance would cause more and more current to be taken as the lamp heated up and the temperature would get higher and higher in a runaway manner until either the power supply's breaker would trip or (more likely) the light bulb's filament would simply burn open. In fact the filament has to be made from a material that has a positive temperature coefficient. (As temperature increases, resistance increases.) Then, as the bulb's temperature rises, its filament's increasing resistance causes less current to be taken than when it was cold. Quite quickly a stable "steady-state" temperature and "running" resistance is reached so that the bulb simply continues to give out a steady amount of light according to the current it is taking from the electricity supply.

Related Questions

Why would a GFCI trip with no load on it?

A GFCI can trip with no load on it due to internal issues, such as a faulty wiring connection or a malfunctioning internal component. This can cause the GFCI to detect a ground fault even when there is no actual fault present, leading to the tripping of the device.


Were was the trip Darwin went to when he discovered a light bulb?

What ?????!


What happens if you trip a GFCI repeatedly on purpose?

Every time you trip the GFCI, the power to the device plugged into it will lose its supply voltage.


Why does the GFCI trip with no load?

The GFCI (Ground Fault Circuit Interrupter) can trip with no load due to internal issues or a ground fault in the circuit. This can happen if there is a problem with the wiring or if the GFCI itself is faulty.


How many amps does gfci trip at?

GFCI receptacles are designed to trip at around 5 milliamps (0.005 amps) of current leakage to ground. When the GFCI detects this level of imbalance, it quickly shuts off the power to prevent electric shock.


How can I troubleshoot a GFCI light that keeps tripping?

To troubleshoot a GFCI light that keeps tripping, first unplug all devices connected to the outlet. Press the "reset" button on the GFCI outlet to see if it resets. If it continues to trip, check for any water leaks or moisture near the outlet. If the problem persists, it may be a faulty GFCI outlet that needs to be replaced by a qualified electrician.


Is a pool spotlight different from a regular outdoor flood light?

yes a pool light is typically a sealed unit. this is to prevent water from entering the light and coming in contact with the electrical components of the light. if water were to enter the light it could damage the light fixture and also trip the light breaker or gfci. in addition in some situations if the light were not installed correctly/electrically protected correctly (with breaker and gfci) could cause a dangerous situation to bathers. to change the light bulb in a pool light fixture the light fixture must be brought above the waters surface and the lense with lense gasket removed bulb changed then lense with lense gasket replaced and the light reinstalled in the light niche in the wall of the pool below the waters surface. you must also use the appropriate bulb for the light fixture. this is not as simple as just picking up a bulb from home depot and threading it in as you would do with an outdoor flood light. light repairs should only be performed by a trained pool professional as it could be dangerous if not done correctly.


How much amperage is needed to trip a 20amp GFCI outlet?

A GFCI trips when it detects a difference in the amperage going to the outlet and what is coming back. Even 4-6 miliamps difference will trip the outlet.


Why does the washer trip the GFCI?

The washer may trip the GFCI due to a ground fault, which means that electricity is flowing through an unintended path, potentially causing a safety hazard.


Why would a condensate pump on a HVAC cause a GFCI to trip?

A condensate pump might trip a GFCI if there is a ground fault or water leakage causing an imbalance in the electrical circuit. The GFCI detects this imbalance and shuts off the power to prevent electric shock. It is important to investigate and resolve the issue to prevent further damage and ensure safety.


How do you check a GFCI breaker to ensure it is functioning properly?

To check a GFCI breaker, press the "Test" button to trip it, then press the "Reset" button to restore power. Use a voltage tester to confirm that the power is off when the GFCI is tripped and on when it is reset. If the GFCI does not trip or reset properly, it may need to be replaced.


Will a GFCI outlet trip when the current is reduced or shut off?

A GFCI outlet will trip when it detects a ground fault, not when the current is simply reduced or shut off. The purpose of the GFCI outlet is to quickly shut off power when it senses a potential electrical hazard, such as a ground fault or leakage.