answersLogoWhite

0

Yes, because you will be able to maintain current flow between phases.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

If you have a 240V 22A welder which has a plug similar but smaller than a dryer plug can you use this in a 120V outlet?

No, a 240V 22A welder requires a 240V outlet for proper operation. Plugging it into a 120V outlet will not provide enough power and could damage the welder or create a safety hazard. It is important to always use the correct voltage and amperage for electrical appliances.


Can you plug a 230v welder into your household socket 240v?

its ok..i found out that it can be done, as long as its not turned up to use more than 130amp.:)


If you have a spa that is 240V with 4 wires can you hook an extension cord from a 240V welder to it to see if it works if the cord only has three wires?

Well, maybe. What is the current rating on the spa circuit? What is the current rating on the welder? If the welder is larger than the outlet, then no. It must be the other way around. If the current ratings are OK, then yes. Your welder doesn't need 110V so it doesn't connext to neutral. Connect the hot leads to hot and ground to ground.


How do you safely connect to a 240V pullout fuse box used for pool equipment located in a detached garage as a temporary power source for a 240V millermatic 250 mig welder?

The voltage is correct, BUT, Your welder is going to draw more current than the pool pump did. The breaker, wiring, and the receptacle will have to be upgraded. In my opinion I have never seen a "temporary" connection!! ...pkazsr


Why three phase meter is better than single phase meter?

A three-phase meter can be used for single phase while the reverse is not the case.


How many 16 Amps per phase welding outlet can you install to a 30 KvA rating transformer?

..the questions does not say wether the 30kVA transformer is 3 phase transformer or single phase transformer..but it is implying that a single phase welding load at 16A per phase is to be connect to it, it is assumed then that the transformer is 3 phase transformer..we assume load is rated 240V.. ..though not much details is given about the transformer voltage specs. but if is rated 3 phase 415/240V, the approx full load current per phase is given by 30KVAx1.3912=41.736A.. ..but if the transformer was rated single phase 240V say, the approx full load current FLC=30000/240V gives 125ampers.. ..if you further devide the FLC by the intended load current.. ..Recommended no of welders per for a 3 phase 415V transformer and assuming single welding sets =41.736/16=2.6..so you can connect max two welding sets to this transformer per phase,..max 6 weld sets can connect at an approx load factor of 76%.. ..for the single phase transformer, FLC/16=125/16, gives 7.8 but is also recommended not to connect more than 6 welding sets to such transformer for the same reasons..


Is South Beach Diet Phase 2 better than South Beach Diet Phase 1?

Yes South Beach Diet Phase 2 is better than South Beach Diet Phase 1 because now in phase 2 you can add back in some of the foods you had to give up in phase 1. If you want a piece of chocolate cake you can have it just in moderation.


Is a welder brighter than the sun?

No, a welder is not brighter than the sun. The sun is a star and emits much more light and energy than any welding process.


How much more efficient is a 2 hp 240 v 3 phase motor compared to a 120 v single phase 2 hp motor?

A 240V 3-phase motor is generally more efficient compared to a 120V single-phase motor of the same horsepower rating because it provides smoother and more consistent power delivery. The 3-phase motor also tends to have lower operating temperatures and reduced energy losses, resulting in higher efficiency and better performance overall.


Why three-phase six pulse rectifier is better than three-phase three pulse rectifier?

By this process all errors to be removed and electricity distribution becomes storng. Rectifier always react all abstraction which law given be Ohms.


How much inch dia can welder weld per day at onshore?

This will depend on the welder in question. Some of them are faster than others and some are a little slower.


What can be used to repair an aluminum line other than welding?

the best way to get a good looking/ strong weld on aluminum is using a tig welder it is also possibles with a mig welder but for best results recommend a tig welder with HF