answersLogoWhite

0

Measurement of flow, whether it is a liquid or gas, is commonly a critical parameter in many processes. In most operations it is important to know that the right fluid is at the right place at the right time. Some critical applications require the ability to conduct accurate flow measurements to ensure product quality. Health & Safety is always an important factor when working with liquids and gases, investment in ensuring your team can operate in a safe and productive environment is very important. Measuring flow and pressure can provide this security to the process and personnel.

User Avatar

zhei thang

Lvl 5
4y ago

What else can I help you with?

Related Questions

The apparent curving of the winds is called?

the Coriolis effect


What apparent shift in wind direction that is caused by the earth rotation?

Coriolis effect


How does the ocean flows?

It Flows with the coriolis effect. It Flows with the coriolis effect.


Is the increased cooling that a wind can cause called the Coriolis effect?

Wind Chill is the scale you need. In the late 1930s a Boy Scout was invited to travel to the Antarctic with Byrd's expedition, and this person was Paul Siple. One of the experiments he devised was to measure the rate of cooling in various wind strengths and temperatures, of water filled bottles. From such simple beginnings, Wind Chill measurement was started.


Who discovered the coriolis force?

The Coriolis force was described by French mathematician and engineer Gaspard-Gustave de Coriolis in 1835. He formulated the concept to explain the deviations in the motion of objects on a rotating surface.


Why did Gaspard Gustave Coriolis named his invention the Coriolis effect?

Gaspard Gustave Coriolis named his invention the Coriolis effect after himself because he was the first to mathematically describe the phenomenon in fluid dynamics. His work on the effect, which explains the deflection of moving objects on a rotating planet, has since become a fundamental concept in meteorology and oceanography.


How does the Coriolis effect affect flight travel in the US?

The Coriolis effect influences flight travel in the US by causing aircraft to deviate from a straight path due to the Earth's rotation. As planes travel over long distances, particularly in the north-south direction, their flight paths are subtly altered, requiring pilots and air traffic controllers to adjust routes for precision. This effect is more pronounced in the upper atmosphere, impacting wind patterns and thus the efficiency of flight routes. Ultimately, understanding the Coriolis effect helps optimize fuel consumption and travel times.


What does Coriolis mean for kids?

Coriolis is a force that affects moving objects on the Earth due to its rotation. It causes objects like air and water to curve instead of moving in a straight line. This effect is important for understanding weather patterns and ocean currents.


what's the Coriolis Flow Meter Working principle?

Coriolis Flow Meter. A single or dual tube is located inside the pipeline of each Coriolis flow meter. An exciter causes the tube to oscillate constantly. If there is now flow, the tube oscillates uniformly. As soon as the flow starts to flow in the tube, an additional twist is imposed on the oscillations as a result of liquid inertia. Sensors are located at the inlet and outlet of the tube and register this basic oscillation precisely. Now due to the Coriolis effect, the inlet and outlet sections of the tube oscillate in different directions at the same time. Highly sensitive sensors pick up this change of time and space. This is called a phase shift. This is a direct measurement of how much gas, the liquid is flowing through the pipe. Higher the phase shift, the more the flow in the tube vice versa. Density can also be measured by measuring the oscillation frequency. The frequency of oscillations for water-filled tube is more, whereas honey-filled tube is less. This is due to the density difference. Advantages: Coriolis flowmeter is insensitive to viscosity, pressure, and temperature. Coriolis flowmeter can be configured to measure flow in either the forward or reverse direction. Coriolis flowmeter can be configured to measure flow in either the forward or reverse direction. Coriolis flowmeters do not have any internal obstructions that can be damaged or plugged by viscous slurries or other types of particulate matter in the flow stream. The operation of the flowmeter does not depend on the Reynolds number. Coriolis flowmeters provide a direct mass flow measurement without the addition of any external measurement instruments. They display outstanding accuracy. The flow meters are highly linear over the entire flow range. Rangeability is on the order of 20:1. Coriolis flowmeters have been successfully applied at flow rates 100 times lower than their rated scale flow rate. The operation of the flow meter is independent of flow characteristics such as turbulence and flow profile. Therefore, the requirement of upstream and downstream straight pipe run requirements and flow conditioning is not required. Limitation of Coriolis Flowmeters: Coriolis flowmeters are expensive. Coriolis flowmeters are difficulty in measuring the flow rate of low-pressure gas. Coriolis flowmeters are not available for the large pipelines.


What is Gaspard-Gustave Coriolis's birthday?

Gaspard-Gustave Coriolis was born on May 21, 1792.


When was Gaspard-Gustave Coriolis born?

Gaspard-Gustave Coriolis was born on May 21, 1792.


What causes the coriolis?

The Coriolis effect is caused by the rotation of the earth.